Estimation of body fluid changes during peritoneal dialysis by segmental bioimpedance analysis

被引:38
作者
Zhu, FS
Schneditz, D
Kaufman, AM
Levin, NW
机构
[1] Graz Univ, Dept Physiol, A-8010 Graz, Austria
[2] Beth Israel Med Ctr, Div Nephrol & Hypertens, New York, NY 10003 USA
[3] Renal Res Inst, New York, NY USA
关键词
dialysis adequacy; conductivity; extracellular volume; regional fluid distribution; peritoneal equilibrium;
D O I
10.1046/j.1523-1755.2000.00815.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. Commonly used bioimpedance analysis (BIA) is insensitive to changes in peritoneal fluid volume. The purpose of this study was to show, to our knowledge for the first time, that a new segmental approach accurately measures extracellular fluid changes during peritoneal dialysis (PD). Methods. Fourteen stable PD patients were studied during a standard exchange with fluids of known conductivity. Bioimpedance was continuously measured in the arm, trunk, and leg and from wrist to ankle. Volume changes were calculated using both a newly developed sum of segmental BIA (SBIA) and current wrist-to-ankle BIA (WBIA) and were compared with actual volume changes measured gravimetrically. Results. When 2.19 +/- 0.48 L were removed from the peritoneal cavity during draining, 95.2 +/- 13.8% of this volume was detected by SBIA compared with only 12.5 +/- 24.3% detected by WBIA. When 2.11 +/- 0.20 L of fresh dialysate was infused into the peritoneal cavity during filling, 91.1 +/- 19.6% of this volume was detected by SBIA compared with only 8.8 +/- 21.1% detected by WBIA. Conclusion. The good agreement between measured and calculated data using SBIA was due to: (a) improved placement of electrodes, (b) estimation of trunk extracellular volume based on a new algorithm, and (c) consideration of changes in dialysate conductivity. Correct estimation of fluid volume in the trunk is a prerequisite for applications in which direct analysis of fluid changes cannot be performed such as with peritoneal equilibration tests and continuous flow PD.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 27 条
[1]  
Arkouche W, 1997, J AM SOC NEPHROL, V8, P1906
[2]   Bioimpedance spectroscopy technique: intra-, extracellular, and total body water [J].
Armstrong, LE ;
Kenefick, RW ;
Castellani, JW ;
Riebe, D ;
Kavouras, SA ;
Kuznicki, JT ;
Maresh, CM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (12) :1657-1663
[3]   Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans [J].
Bracco, D ;
Thiebaud, D ;
Chiolero, RL ;
Landry, M ;
Burckhardt, P ;
Schutz, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2580-2587
[4]  
DELORENZO A, 1994, RENAL PHYSIOL BIOCH, V17, P326
[5]   Predicting body cell mass with bioimpedance by using theoretical methods: A technological review [J].
DeLorenzo, A ;
Andreoli, A ;
Matthie, J ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) :1542-1558
[6]  
Dumler F, 1997, ASAIO J, V43, P256
[7]   Assessment of excess fluid distribution in chronic hemodialysis patients using bioimpedance spectroscopy [J].
Fisch, BJ ;
Spiegel, DM .
KIDNEY INTERNATIONAL, 1996, 49 (04) :1105-1109
[8]   Extracellular and intracellular fluid volume monitoring during dialysis by multifrequency impedancemetry [J].
Jaffrin, MY ;
Maasrani, M ;
Boudailliez, B ;
LeGourrier, A .
ASAIO JOURNAL, 1996, 42 (05) :M533-M538
[9]   Monitoring of extracellular and total body water during haemodialysis using multifrequency bio-electrical impedance analysis [J].
Johnson, DW ;
Thomas, BJ ;
Fleming, SJ ;
Westhuyzen, J ;
Moran, D ;
Ward, LC .
KIDNEY & BLOOD PRESSURE RESEARCH, 1996, 19 (02) :94-99
[10]   Extracellular fluid volume determined by bioelectric impedance and serum albumin in CAPD patients [J].
Jones, CH ;
Smye, SW ;
Newstead, CG ;
Will, EJ ;
Davison, AM .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (02) :393-397