Design, fabrication and characterization of a conducting PDMS for microheaters and temperature sensors

被引:60
作者
Chuang, Han-Sheng [1 ,2 ]
Wereley, Steven [1 ,2 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[2] Birck Nanotechnol Ctr, W Lafayette, IN 47907 USA
关键词
SOFT-LITHOGRAPHY; CARBON-BLACK; POLY(DIMETHYLSILOXANE); VALVES;
D O I
10.1088/0960-1317/19/4/045010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present the design and fabrication procedure of a conducting polydimethylsiloxane (PDMS) and then evaluate its potential uses for heating and temperature sensing. The conducting PDMS was made up of a mixture of a PDMS prepolymer and metallic powder. Depending on purpose, i.e. heater or sensor, different weight ratios of the powder and geometric shapes were considered. Characterization of both the microheaters and the temperature sensors includes stability, repeatability, durability and time response. The results suggest that the microheater is feasible for constantly heating at a fixed temperature instead of running thermal cycles. The optimal heating range was estimated below 100 degrees C under the current setup and a power consumption of 210 +/- 12 mW was needed for 92 degrees C. Hysteresis and time lag were observed in the temperature sensor. Accordingly, the sensor is recommended to be used for long-term monitoring instead of rapid temperature detections.
引用
收藏
页数:7
相关论文
共 21 条
[1]  
Amin A M, 2007, 11 INT C MIN SYST CH
[2]  
[Anonymous], P 28 IEEE EMBS ANN I
[3]   High-frequency ultrasound array element using thermoelastic expansion in an elastomeric film [J].
Buma, T ;
Spisar, M ;
O'Donnell, M .
APPLIED PHYSICS LETTERS, 2001, 79 (04) :548-550
[4]  
CHEN J, 1999, J APPL POLYM SCI, V41, P2437
[5]  
Chuang H S, 2008, 12 INT C MIN SYST CH
[6]  
ENGEL J, 2006, 12 SOL STAT SENS ACT
[7]   Development and multiplexed control of latching pneumatic valves using microfluidic logical structures [J].
Grover, WH ;
Ivester, RHC ;
Jensen, EC ;
Mathies, RA .
LAB ON A CHIP, 2006, 6 (05) :623-631
[8]   Rapid PCR in a continuous flow device [J].
Hashimoto, M ;
Chen, PC ;
Mitchell, MW ;
Nikitopoulos, DE ;
Soper, SA ;
Murphy, MC .
LAB ON A CHIP, 2004, 4 (06) :638-645
[9]   Low-cost, low-loss microlens arrays fabricated by soft-lithography replication process [J].
Kunnavakkam, MV ;
Houlihan, FM ;
Schlax, M ;
Liddle, JA ;
Kolodner, P ;
Nalamasu, O ;
Rogers, JA .
APPLIED PHYSICS LETTERS, 2003, 82 (08) :1152-1154
[10]   Reliable fabrication method of transferable micron scale metal pattern for poly(dimethylsiloxane) metallization [J].
Lim, KS ;
Chang, WJ ;
Koo, YM ;
Bashir, R .
LAB ON A CHIP, 2006, 6 (04) :578-580