Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene

被引:135
作者
Anissian, HL [1 ]
Stark, A
Gustafson, A
Good, V
Clarke, IC
机构
[1] Karolinska Hosp, Dept Orthopaed Surg, SE-17176 Stockholm, Sweden
[2] Loma Linda Univ, Med Ctr, Dept Orthopaed Surg, Loma Linda, CA 92350 USA
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1999年 / 70卷 / 06期
关键词
D O I
10.3109/17453679908997845
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aseptic loosening due to osteolysis in total hip replacement has been related to wear debris released from prosthetic components. Retrospective longterm observations of patients with the metal-on-metal prosthesis has shown long-term survivorship and good mechanical performance. Thus, the new and modified metal-on-metal prosthesis has been introduced on the market. Historical clinical data from the 1st generation metal-on-metal hip prosthesis may not be relevant for the 2nd generation of metal-on-metal hip prosthesis. Therefore, preclinical testing of the prosthesis must be conducted before clinical evaluation. We assessed the tribological performance of the metal-on-metal prosthesis versus the metal-on-polyethylene prosthesis introduced on the market as Metasul(TM) and Protasul(TM), respectively. In a 12-channel joint simulator, 6 metal-on-metal bearing and 3 metal on polyethylene prostheses were tested, with the same number of corresponding soak controls. The wear was assessed gravimetrically. The "steady-state" wear-rates from the metal-on-metal prosthesis were almost 100 times less than that from the metal-on-polyethylene prosthesis. The tribological wear performance of the metal-on-metal hip prosthetic system is promising.
引用
收藏
页码:578 / 582
页数:5
相关论文
共 26 条
[1]  
Amstutz H. C., 1996, CLIN ORTHOP S, V329, P11
[2]  
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, V18, P276
[3]  
BLACK J, 1996, CLIN ORTHOP S, V329, P244, DOI DOI 10.1097/00003086-199608001-00021
[4]  
Bouchard PR, 1996, J BIOMED MATER RES, V32, P37, DOI 10.1002/(SICI)1097-4636(199609)32:1<37::AID-JBM5>3.0.CO
[5]  
2-Q
[6]   Hip-simulator ranking of polyethylene wear - Comparisons between ceramic heads of different sizes [J].
Clarke, IC ;
Gustafson, A ;
Jung, H ;
Fujisawa, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02) :128-132
[7]   Kieron Walsh [J].
Clarke, M ;
Stewart, J .
PUBLIC MONEY & MANAGEMENT, 1996, 16 (01) :8-8
[8]  
Engesaeter Lars B., 1996, Tidsskrift for den Norske Laegeforening, V116, P3025
[9]   Early osteolysis with Hylamer acetabular liners [J].
Graeter, JH ;
Nevins, R .
JOURNAL OF ARTHROPLASTY, 1998, 13 (04) :464-466
[10]  
JACOBS JJ, 1996, 42 ANN M ORTH RES SO, P498