A dose-response curve for the negative bias pressure of an intrathoracic pressure regulator during CPR

被引:7
作者
Babbs, Charles F.
Yannopoulos, Demetris
机构
[1] Purdue Univ, Dept Basic Med Sci, W Lafayette, IN 47907 USA
[2] Indiana Univ, Sch Med, Indianapolis, IN 46204 USA
[3] Univ Minnesota, Dept Cardiol, Minneapolis, MN USA
关键词
airway management; ACD-CPR; cardiopulmonary resuscitation (CPR); coronary perfusion pressure; decompression; device; impedance; mathematical model; threshold; valve;
D O I
10.1016/j.resuscitation.2006.01.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
An intrathoracic pressure regulator (ITPR) is a device that can be added to the external end of a tracheal tube to create controlled negative airway pressure between positive pressure ventilations. The resulting downward bias of the airway pressure baseline promotes increased venous return and enhanced circulation during CPR and also during hypovolemic shock. In the present study, we exercised a mathematical model of the human cardiopulmonary system, including airways, lungs, a four chambered heart, great vessels, peripheral vascular beds, and the biomechanics of chest compression and recoil, to determine the relationship between systemic perfusion pressure during CPR and the value of baseline negative airway pressure in an ITPR. Perfusion pressure increases approximately 50% as baseline airway pressure falls from zero to -10 cm H2O. Thereafter perfusion pressure plateaus. Negative bias pressures exceeding -10cm H2O are not needed in ITPR-CPR. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:365 / 368
页数:4
相关论文
共 23 条
[1]   A rationale for staged teaching of basic life support [J].
Assar, D ;
Chamberlain, D ;
Colquhoun, M ;
Donnelly, P ;
Handley, AJ ;
Leaves, S ;
Kern, KB ;
Mayor, S .
RESUSCITATION, 1998, 39 (03) :137-143
[2]   Randomised controlled trials of staged teaching for basic life support - 1. Skill acquisition at bronze stage [J].
Assar, D ;
Chamberlain, D ;
Colquhoun, M ;
Donnelly, P ;
Handley, AJ ;
Leaves, S ;
Kern, KB .
RESUSCITATION, 2000, 45 (01) :7-15
[3]   Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest [J].
Aufderheide, TP ;
Pirrallo, RG ;
Provo, TA ;
Lurie, KG .
CRITICAL CARE MEDICINE, 2005, 33 (04) :734-740
[4]   Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques [J].
Aufderheide, TP ;
Pirrallo, RG ;
Yannopoulos, D ;
Klein, JP ;
von Briesen, C ;
Sparks, CW ;
Deja, KA ;
Conrad, CJ ;
Kitscha, DJ ;
Provo, TA ;
Lurie, KG .
RESUSCITATION, 2005, 64 (03) :353-362
[5]   Effects of an impedance threshold valve upon hemodynamics in Standard CPR: Studies in a refined computational model [J].
Babbs, CF .
RESUSCITATION, 2005, 66 (03) :335-345
[6]   Optimizing chest compression to rescue ventilation ratios during one-rescuer CPR by professionals and lay persons: children are not just little adults [J].
Babbs, CF ;
Nadkarni, V .
RESUSCITATION, 2004, 61 (02) :173-181
[7]   Meta-analysis of 2-treatment clinical trials including both continuous and dichotomous results [J].
Babbs, CF .
MEDICAL DECISION MAKING, 2004, 24 (03) :299-312
[8]   Simplified meta-analysis of clinical trials in resuscitation [J].
Babbs, CF .
RESUSCITATION, 2003, 57 (03) :245-255
[9]  
BABBS CF, 1986, CIRCULATION, V74, P37
[10]  
Babbs Charles E., 2002, Cardiology Clinics, V20, P37, DOI 10.1016/S0733-8651(03)00064-X