Spectrophotometric determination of beryllium in water samples after micelle-mediated extraction preconcentration

被引:55
作者
Afkhami, Abbas [1 ]
Madrakian, Tayyebeh
Bozorgzadeh, Elaheh
Bahram, Morteza
机构
[1] Bu Ali Sina Univ, Dept Chem, Fac Sci, Hamadan, Iran
[2] Urmia Univ, Dept Chem, Fac Sci, Orumiyeh, Iran
关键词
beryllium determination; micelle-mediated extraction; chrome azurol S; spectrophtometry; mean centering;
D O I
10.1016/j.talanta.2006.06.004
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A new micelle-mediated phase preconcentration method for preconcentration of ultra-trace quantities of beryllium as a prior step to its determination by spectrophotometry has been developed. Chrome Azurol S (CAS) and cetyltrimethylammonium bromide (CTAB) were used as chelating agent and cationic surfactant, respectively. The method evaluates and eliminates the blank bias error present in such procedures using mean centering of ratio spectra. This procedure gives more accurate results than the traditional approach using absorbance values against reagent blank. The optimal extraction and reaction conditions were studied and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration and improvement factors) were obtained. Linearity was obeyed in the range of 0.9-18.0 ng mL(-1) (1.00 x 10(-7) -2.00 x 10(-6) mol L-1) of beryllium. The detection limit of the method is 0.51 ng mL(-1) (5.66 x 10(-8) mol L-1) of beryllium. The interference effect of some anions and cations was also tested. The method was applied to the determination of beryllium in spring water samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1103 / 1109
页数:7
相关论文
共 45 条
[1]
A novel spectrophotometric method for the simultaneous kinetic analysis of ternary mixtures by mean centering of ratio kinetic profiles [J].
Afkhami, A ;
Bahram, M .
TALANTA, 2006, 68 (04) :1148-1155
[2]
Simultaneous kinetic determination of beryllium and aluminium by spectrophotometric H-point standard addition method [J].
Afkhami, A ;
Zarei, AR .
ANALYTICAL SCIENCES, 2004, 20 (12) :1711-1715
[3]
Simultaneous spectrophotometric determination of iodate and bromate in water samples by the method of mean centering of ratio kinetic profiles [J].
Afkhami, A ;
Madrakian, T ;
Bahram, M .
JOURNAL OF HAZARDOUS MATERIALS, 2005, 123 (1-3) :250-255
[4]
Mean centering of ratio spectra as a new spectrophotometric method for the analysis of binary and ternary mixtures [J].
Afkhami, A ;
Bahram, M .
TALANTA, 2005, 66 (03) :712-720
[5]
Mean centering of ratio kinetic profiles as a novel spectrophotometric method for the simultaneous kinetic analysis of binary mixtures [J].
Afkhami, A ;
Bahram, M .
ANALYTICA CHIMICA ACTA, 2004, 526 (02) :211-218
[6]
Solid phase extraction flame atomic absorption spectrometric determination of ultra-trace beryllium [J].
Afkhami, A ;
Madrakian, T ;
Assl, AA ;
Sehhat, AA .
ANALYTICA CHIMICA ACTA, 2001, 437 (01) :17-22
[7]
*AM PUBL HLTH ASS, 1995, STAND METH EX WAT WA, P15
[8]
Small-angle neutron-scattering and viscosity studies of CTAB/NaSal viscoelastic micellar solutions [J].
Aswal, VK ;
Goyal, PS ;
Thiyagarajan, P .
JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (14) :2469-2473
[9]
Booij H.L., 1949, COLLOID SCI 2 ASS CO, P681
[10]
BURBA P, 1983, INT J ENVIRON AN CH, V13, P177, DOI 10.1080/03067318308071592