Detection of Hypoglycemia with Continuous Interstitial and Traditional Blood Glucose Monitoring Using the FreeStyle Navigator Continuous Glucose Monitoring System

被引:21
作者
McGarraugh, Geoffrey [1 ]
Bergenstal, Richard [2 ]
机构
[1] Abbott Diabet Care, Alameda, CA 94502 USA
[2] Int Diabet Ctr, Minneapolis, MN USA
关键词
D O I
10.1089/dia.2008.0047
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The objective of the analysis was to compare detection of hypoglycemic episodes (glucose <70 mg/dL lasting >15 min) with the FreeStyle Navigator (R) Continuous Glucose Monitoring System (FSN-CGM) (Abbott Diabetes Care, Alameda, CA) alarms to detection with traditional finger stick testing at an average frequency of eight tests per day. Methods: The performance of FSN-CGM alarms was evaluated in a clinic setting using 58 subjects with type 1 diabetes mellitus (T1DM) monitoring interstitial glucose concentration over a 5-day period compared to reference YSI measurements (instrument manufactured by YSI, Yellow Springs, OH) at 15-min intervals. Finger stick glucose testing was evaluated in the home environment with 91 subjects with TIDM monitoring with the blood glucose meter integrated into the FreeStyle Navigator (FSN-BG) over a 20-day period. The reference was FSN-CGM with results masked from the subjects. Blood glucose values <= 85 mg/dL were considered the optimal treatment level to avoid or reverse hypoglycemia. Results: With a threshold alarm setting of 85 mg/dL, 90.6% of hypoglycemic episodes were detected within +/- 30 min by FSN-CGM in the clinic study. When the alarm was activated, YSI glucose was <= 85 mg/dL 77.2% of the time. In the home environment, the average FSN-BG testing frequency was 7.9 tests per day. Hypoglycemia was verified within +/- 30 min by FSN-BG measurements <= 85 mg/dL at a rate of 27.5%. Conclusions: Even with a high rate of FSN-BG testing, hypoglycemia detected by FSN-CGM was verified by patients with T1DM very infrequently. A high rate of hypoglycemia detection with a moderate rate of unnecessary alarms can be attained using FSN-CGM.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 7 条
[1]  
[Anonymous], 2003, 151972003 ISO
[2]  
Burtis Carl A., 1999, Teitz Textbook of Clinical Chemistry, V3rd
[3]   Hypoglycemia in diabetes [J].
Cryer, PE ;
Davis, SN ;
Shamoon, H .
DIABETES CARE, 2003, 26 (06) :1902-1912
[4]  
Feldman Ben, 2003, Diabetes Technol Ther, V5, P769, DOI 10.1089/152091503322526978
[5]   Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type I diabetes [J].
McGowan, K ;
Thomas, W ;
Moran, A .
DIABETES CARE, 2002, 25 (09) :1499-1503
[6]   THE EFFECT OF INTENSIVE TREATMENT OF DIABETES ON THE DEVELOPMENT AND PROGRESSION OF LONG-TERM COMPLICATIONS IN INSULIN-DEPENDENT DIABETES-MELLITUS [J].
SHAMOON, H ;
DUFFY, H ;
FLEISCHER, N ;
ENGEL, S ;
SAENGER, P ;
STRELZYN, M ;
LITWAK, M ;
WYLIEROSETT, J ;
FARKASH, A ;
GEIGER, D ;
ENGEL, H ;
FLEISCHMAN, J ;
POMPI, D ;
GINSBERG, N ;
GLOVER, M ;
BRISMAN, M ;
WALKER, E ;
THOMASHUNIS, A ;
GONZALEZ, J ;
GENUTH, S ;
BROWN, E ;
DAHMS, W ;
PUGSLEY, P ;
MAYER, L ;
KERR, D ;
LANDAU, B ;
SINGERMAN, L ;
RICE, T ;
NOVAK, M ;
SMITHBREWER, S ;
MCCONNELL, J ;
DROTAR, D ;
WOODS, D ;
KATIRGI, B ;
LITVENE, M ;
BROWN, C ;
LUSK, M ;
CAMPBELL, R ;
LACKAYE, M ;
RICHARDSON, M ;
LEVY, B ;
CHANG, S ;
HEINHEINEMANN, M ;
BARRON, S ;
ASTOR, L ;
LEBECK, D ;
BRILLON, D ;
DIAMOND, B ;
VASILASDWOSKIN, A ;
LAURENZI, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :977-986
[7]   Accuracy of the 5-day freestyle navigator continuous glucose monitoring system - Comparison with frequent laboratory reference measurements [J].
Weinstein, Richard L. ;
Bugler, Jolyon R. ;
Schwartz, Sherwyn L. ;
Peyser, Thomas A. ;
Brazg, Ronald L. ;
McGarraugh, Geoffrey V. .
DIABETES CARE, 2007, 30 (05) :1125-1130