Helical and conventional CT in the imaging of metallic foreign bodies in the orbit

被引:29
作者
Lakits, A
Prokesch, R
Scholda, C
Nowotny, R
Kaider, A
Bankier, A
机构
[1] Univ Vienna, Sch Med, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
[3] Univ Vienna, Dept Biomed Engn & Phys, A-1090 Vienna, Austria
[4] Univ Vienna, Dept Med Comp Sci, A-1090 Vienna, Austria
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 2000年 / 78卷 / 01期
关键词
Computed Tomography; helical CT; orbit; foreign body; metallic; imaging;
D O I
10.1034/j.1600-0420.2000.078001079.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare helical CT to conventional CT imaging in the assessment of orbital metallic foreign bodies with regard to image quality, scanning time, and radiation exposure. Methods: Twenty-four standardized metallic foreign bodies, placed into the orbit (anterior, epibulbar, posterior) of cadaver heads were studied. Helical CT scanning in the axial plane with multiplanar reconstruction of coronal and sagittal images was performed as well as conventional CT imaging with direct scanning in the axial and the coronal planes (Tomoscan SR 7000, Philips, The Netherlands). Two masked observers consensually graded the studies using 5 predetermined criteria, Radiation dose delivered to the lens and scanning time were measured for the helical and the conventional CT imaging workup, Results: Helical CT imaging scored statistically significantly better with regard to overall accuracy of foreign body localization and presence of beam-hardening streak artifacts from dental fillings, Conventional CT scored significantly better with regard to stair-step artifacts, The radiation dose delivered to the lens was 35.4 mGy for helical CT imaging and 73.9 mGy for conventional CT workup (axial and coronal scanning). Total scanning time was 18 seconds for helical CT axial scanning and 104 seconds for conventional CT axial and coronal scanning. Conclusion: Helical CT is superior to conventional CT imaging, because it can provide adequate information about orbital metallic foreign bodies with a single acquisition, thus reducing both the number of examinations and the radiation exposure for the patient.
引用
收藏
页码:79 / 83
页数:5
相关论文
共 14 条
[1]   Detection and localization of steel intraocular foreign bodies using computed tomography - A comparison of helical and conventional axial scanning [J].
Chacko, JG ;
Figueroa, RE ;
Johnson, MH ;
Marcus, DM ;
Brooks, SE .
OPHTHALMOLOGY, 1997, 104 (02) :319-323
[2]   Projectile metallic foreign bodies in the orbit - A retrospective study of epidemiologic factors, management, and outcomes [J].
Finkelstein, M ;
Legmann, A ;
Rubin, PAD .
OPHTHALMOLOGY, 1997, 104 (01) :96-103
[3]  
GROVE AS, 1982, OPHTHALMOLOGY, V89, P433
[4]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656
[5]   The quality of 3D reconstructions from 1.0 and 1.5 pitch helical and conventional CT [J].
Hopper, KD ;
Pierantozzi, D ;
Potok, PS ;
Kasales, CJ ;
TenHave, TR ;
Meilstrup, JW ;
VanSlyke, MA ;
Mahraj, R ;
Westacott, S ;
Hartzel, JS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) :841-847
[6]   PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING [J].
KALENDER, WA ;
POLACIN, A .
MEDICAL PHYSICS, 1991, 18 (05) :910-915
[7]   Evaluation of intraocular foreign bodies by spiral computed tomography and multiplanar reconstruction [J].
Lakits, A ;
Steiner, E ;
Scholda, C ;
Kontrus, M .
OPHTHALMOLOGY, 1998, 105 (02) :307-312
[8]   Multiplanar imaging in the preoperative assessment of metallic intraocular foreign bodies - Helical computed tomography versus conventional computed tomography [J].
Lakits, A ;
Prokesch, R ;
Scholda, C ;
Bankier, A ;
Weninger, F ;
Imhof, H .
OPHTHALMOLOGY, 1998, 105 (09) :1679-1685
[9]  
LOBES LA, 1981, OPHTHALMOLOGY, V88, P26
[10]   COMPARISON OF HELICAL AND SERIAL CT WITH REGARD TO 3-DIMENSIONAL IMAGING OF MUSCULOSKELETAL ANATOMY [J].
NEY, DR ;
FISHMAN, EK ;
KAWASHIMA, A ;
ROBERTSON, DD ;
SCOTT, WW .
RADIOLOGY, 1992, 185 (03) :865-869