Three-dimensional focus of attention for iterative cone-beam micro-CT reconstruction

被引:17
作者
Benson, T. M. [1 ]
Gregor, J. [1 ]
机构
[1] Univ Tennessee, Dept Comp Sci, Knoxville, TN 37996 USA
关键词
D O I
10.1088/0031-9155/51/18/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional iterative reconstruction of high-resolution, circular orbit cone-beam x-ray CT data is often considered impractical due to the demand for vast amounts of computer cycles and associated memory. In this paper, we show that the computational burden can be reduced by limiting the reconstruction to a small, well-defined portion of the image volume. We first discuss using the support region defined by the set of voxels covered by all of the projection views. We then present a data-driven preprocessing technique called focus of attention that heuristically separates both image and projection data into object and background before reconstruction, thereby further reducing the reconstruction region of interest. We present experimental results for both methods based on mouse data and a parallelized implementation of the SIRT algorithm. The computational savings associated with the support region are substantial. However, the results for focus of attention are even more impressive in that only about one quarter of the computer cycles and memory are needed compared with reconstruction of the entire image volume. The image quality is not compromised by either method.
引用
收藏
页码:4533 / 4546
页数:14
相关论文
共 20 条
[1]  
Benson T, 2004, J X-RAY SCI TECHNOL, V12, P231
[2]   Framework for iterative cone-beam micro-CT reconstruction [J].
Benson, TM ;
Gregor, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) :1335-1340
[3]   Statistical image reconstruction for polyenergetic X-ray computed tomography [J].
Elbakri, IA ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :89-99
[5]  
Gonzalez R., 2019, Digital Image Processing, V2nd
[6]   Angular weighted hybrid cone-beam CT reconstruction for circular trajectories [J].
Grass, M ;
Köhler, T ;
Proksa, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06) :1595-1610
[7]   3D cone-beam CT reconstruction for circular trajectories [J].
Grass, M ;
Köhler, T ;
Proksa, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :329-347
[8]   Fast Feldkamp reconstruction based on focus of attention and distributed computing [J].
Gregor, J ;
Gleason, SS ;
Paulus, MJ ;
Cates, J .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2002, 12 (06) :229-234
[9]   Three-dimensional support function estimation and application for projection magnetic resonance imaging [J].
Gregor, J ;
Rannou, FR .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2002, 12 (01) :43-50
[10]   A focus-of-attention preprocessing scheme for EM-ML PET reconstruction [J].
Gregor, J ;
Huff, DA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :218-223