In-house method validation: application in arsenic analysis

被引:24
作者
de Souza, Scheilla V. C.
Pinto, Carlos T.
Junqueira, Roberto G.
机构
[1] Univ Fed Minas Gerais, FAFAR, Dept Alimentos, BR-31270010 Belo Horizonte, MG, Brazil
[2] MAPA LANAGRO MG, Minst Agr Pscuaria & Abastecimento, BR-33600000 Pedro Leopoldo, MG, Brazil
关键词
in-house method validation; food analysis; arsenic; bovine liver; atomic absorption spectrometry; flow injection; hydride generation;
D O I
10.1016/j.jfca.2006.09.002
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A detailed procedure for in-house method validation was proposed and applied to the validation of a method for determination of arsenic in bovine liver. Linearity and matrix effects were assessed by solvent and matrix-matched curves. Data were fitted by ordinary least squares method (OLSM). Violations of assumptions underlying OLSM residuals (normality, independence and homoscedasticity) were evaluated. F-tests were undertaken to check the adjustment to the model by evaluation of regression and lack of fit significances. The slopes and interceptions were compared for significant differences by t-test. Linearity was demonstrated and significant matrix effects were not observed between 0.5 and 8 ng mL(-1). Selectivity, trueness, precision and experimental limits of the method were established by assays with blanks and spiked samples. Recovery (means of 88.9-99.9%) was calculated and analysis of variance was carried out to estimate the standard deviation under repeatability (3.7-7.2%) and within-reproducibility (3.7-7.3%) conditions. The spiking experiments indicated precision and no lack of trueness. Experimental limits of detection and quantification were 15 and 30 mu g kg(-1), respectively. The procedure was found to be suitable for in-house validation with respect to the evaluation of efficiency parameters, ease of application and cost-benefits. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 31 条
[1]  
[Anonymous], 2005, General Requirements for the competence of testing and calibration laboratories, V2nd
[2]   GRAPHS IN STATISTICAL-ANALYSIS [J].
ANSCOMBE, FJ .
AMERICAN STATISTICIAN, 1973, 27 (01) :17-21
[3]  
Armitage P., 2001, STAT METHODS MED RES, V4th
[4]  
BARRET V, 1994, OUTLIERS STAT DATA
[5]  
Belsley D. A., 1980, REGRESSION DIAGNOSTI
[6]  
Brasil, 2005, PORT NO2439 GM 8 DEZ, P1
[7]   ROBUST TESTS FOR EQUALITY OF VARIANCES [J].
BROWN, MB ;
FORSYTHE, AB .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1974, 69 (346) :364-367
[8]   A procedure to assess linearity by ordinary least squares method [J].
de Souza, SVC ;
Junqueira, RG .
ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) :25-35
[9]  
Draper N., 2014, Applied Regression Analysis
[10]  
DURBIN J, 1951, BIOMETRIKA, V38, P159, DOI 10.2307/2332325