Misleading statistical calculations in far-advanced glaucomatous visual field loss

被引:44
作者
Blumenthal, EZ
Sapir-Pichhadze, R
机构
[1] Hadassah Univ Hosp, Dept Ophthalmol, IL-91120 Jerusalem, Israel
[2] Hebrew Univ Jerusalem, Hadassah Med Sch, IL-91010 Jerusalem, Israel
关键词
D O I
10.1016/S0161-6420(02)01297-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: In this study, the capability of statistical analysis indices to characterize static automated visual fields (VFs) accurately in cases of far-advanced glaucoma was assessed. Design: Retrospective observational case series. Participants: Sixteen eyes of 15 patients with end-stage glaucoma and evidence of collapse of VF statistical analysis indices were included in the study. Methods: End-stage glaucoma was defined as vertical cup-to-disc ratio of 0.9 or more, mean deviation less than -24 dB and with only a central or temporal island remaining in the VF gray scale. Collapse of statistical indices was defined as any of the following: pattern deviation probability plot without a single VF location showing P < 0.5%; corrected pattern standard deviation (CPSD) and pattern standard deviation (PSD) probability less than 5% or within normal limits (WNL); short-term fluctuation (SF) probability WNL; glaucoma hemifield test (GHT) not outside normal limits (ONL); or presence of a low patient reliability comment triggered by 40% or more false-negative (FN) responses. Main Outcome Measures: Visual field statistical indices. Results: Of the 16 VFs showing misleading statistical calculations, 9 of 16 eyes had a normal pattern deviation probability plot. The PSD, SF, and CPSD parameters were normal or barely outside the normal range in 4 of 16, 10 of 16, and 5 of 16 eyes, respectively. The GHT was ONL in 7 of 13 eyes, borderline with generalized reduction of sensitivity (GRS) in three eyes, and only GRS in two additional eyes. Low patient reliability was triggered because of an FN score of 40% or more in 10 of 16 eyes. Conclusions: Statistical indices are crucial for the interpretation of automated static VFs. However, in end-stage glaucomatous VF loss, both summary statistical indices and reliability indices may not detect abnormality, thus misleading the casual observer. (C) 2003 by the American Academy of Ophthalmology.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 9 条
[1]  
Anderson D., 1999, AUTOMATED STATIC PER, P121
[2]   EVALUATION OF METHODS FOR AUTOMATED HEMIFIELD ANALYSIS IN PERIMETRY [J].
ASMAN, P ;
HEIJL, A .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (06) :820-826
[3]   GLAUCOMA HEMIFIELD TEST - AUTOMATED VISUAL-FIELD EVALUATION [J].
ASMAN, P ;
HEIJL, A .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (06) :812-819
[4]  
Asman P, 1992, ACTA OPHTHALMOL S, V206, P1
[5]  
Bengtsson B, 2000, INVEST OPHTH VIS SCI, V41, P2201
[6]   DIFFERENTIAL LIGHT THRESHOLD IN AUTOMATED STATIC PERIMETRY - FACTORS INFLUENCING SHORT-TERM FLUCTUATION [J].
FLAMMER, J ;
DRANCE, SM ;
FANKHAUSER, F ;
AUGUSTINY, L .
ARCHIVES OF OPHTHALMOLOGY, 1984, 102 (06) :876-879
[7]  
KATZ J, 1991, OPHTHALMOLOGY, V98, P70
[8]  
Smith SD, 1996, INVEST OPHTH VIS SCI, V37, P1419
[9]  
Spry PGD, 2000, INVEST OPHTH VIS SCI, V41, P2192