Comparison of two blood pool contrast agents for 0.5-T MR angiography: Experimental study in rabbits

被引:48
作者
Clarke, SE
Weinmann, HJ
Dai, EB
Lucas, AR
Rutt, BK
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Schering Contrast Media Res Labs, Berlin, Germany
关键词
contrast media; comparative studies; experimental studies; gadolinium; iron; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.214.3.r00mr25787
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate two experimental blood pool agents for potential use in equilibrium phase abdominal magnetic resonance (MR) angiography. MATERIALS AND METHODS: MR imaging at 0.5 T was performed in 37 rabbits before and after intravenous injection of a gadolinium-based blood pool contrast agent (SH L 643 A), superparamagnetic iron oxide blood pool agent (SH U 555 C), or gadopentetate dimeglumine. T1-weighted fast spoiled gradient-echo images from the renal arteries to below the iliac bifurcation were obtained. The aorta-to-tissue signal difference-to-noise ratio (SDNR) was measured over time. RESULTS: Both blood pool agents yielded excellent demonstration of the rabbit abdominal aorta. At a dose of 0.1 mmol/kg, both provided a statistically significant increase in aorta-to-tissue DNR in comparison with that achieved with gadopentetate dimeglumine (200% increase for SH L 643 A, 95% increase for SH U 555 C; P < .05). A 0.1 mmol/kg dose of SH L 643 A provided a 24% increase in SDNR relative to the increase with a 0.37 mmol/kg dose of gadopentetate dimeglumine. Time-dependent enhancement properties of the blood pool agents differed due to differences in elimination method. CONCLUSION: Both blood pool agents were found to be promising contrast agents for 0.5-T MR angiography; however, their clinical applicability warrants further investigation. The gadolinium-based agent had several advantages over the iron oxide compound, including less T2* dephasing, lack of susceptibility artifacts, and fast renal elimination.
引用
收藏
页码:787 / 794
页数:8
相关论文
共 25 条
[1]   Differentiation of spontaneous canine breast tumors using dynamic magnetic resonance imaging with 24-gadolinium-DTPA-cascade-polymer, a new blood-pool agent - Preliminary experience [J].
Adam, G ;
Muhler, A ;
Spuntrup, E ;
Neuerburg, JM ;
Kilbinger, M ;
Bauer, H ;
Fucezi, L ;
Kupper, W ;
Gunther, RW .
INVESTIGATIVE RADIOLOGY, 1996, 31 (05) :267-274
[2]   GD-DTPA-CASCADE-POLYMER - POTENTIAL BLOOD-POOL CONTRAST AGENT FOR MR-IMAGING [J].
ADAM, G ;
NEUERBURG, J ;
SPUNTRUP, E ;
MUHLER, A ;
SCHERER, K ;
GUNTHER, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :462-466
[3]   Magnetic resonance angiography with gadomer-17 - An animal study original investigation [J].
Dong, Q ;
Hurst, DR ;
Weinmann, HJ ;
Chenevert, TL ;
Londy, FJ ;
Prince, MR .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :699-708
[4]   Contrast-enhanced 3D-TOF MRA of peripheral vessels: Intravascular versus extracellular MR contrast media [J].
Engelbrecht, MR ;
Saeed, M ;
Wendland, MF ;
Canet, E ;
Oksendal, AN ;
Higgins, CB .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :616-621
[5]   ENHANCEMENT OF MR-ANGIOGRAPHY WITH IRON-OXIDE - PRELIMINARY STUDIES IN WHOLE-BLOOD PHANTOM AND IN ANIMALS [J].
FRANK, H ;
WEISSLEDER, R ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :209-213
[6]   THEORY OF 1/T-1 AND 1/T-2 NMRD PROFILES OF SOLUTIONS OF MAGNETIC NANOPARTICLES [J].
KOENIG, SH ;
KELLAR, KE .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :227-233
[7]   MR imaging of the liver with resovist: Safety, efficacy, and pharmacodynamic properties [J].
Kopp, AF ;
Laniado, M ;
Dammann, F ;
Stern, W ;
Gronewaller, E ;
Balzer, T ;
Schimpfky, C ;
Claussen, CD .
RADIOLOGY, 1997, 204 (03) :749-756
[8]   Magnetic iron oxide particles coated with carboxydextran for parenteral administration and liver contrasting - Pre-clinical profile of SH U555A [J].
Lawaczeck, R ;
Bauer, H ;
Frenzel, T ;
Hasegawa, M ;
Ito, Y ;
Kito, K ;
Miwa, N ;
Tsutsui, H ;
Volger, H ;
Weinmann, HJ .
ACTA RADIOLOGICA, 1997, 38 (04) :584-597
[9]   Three-dimensional MRI of coronary arteries using an intravascular contrast agent [J].
Li, DB ;
Dolan, RP ;
Walovitch, RC ;
Lauffer, RB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :1014-1018
[10]   Carboxymethyl-dextran-gadolinium-DTPA as a blood-pool contrast agent for magnetic resonance angiography - Experimental study in rabbits [J].
Loubeyre, P ;
Canet, E ;
Zhao, SH ;
Benderbous, S ;
Amiel, M ;
Revel, D .
INVESTIGATIVE RADIOLOGY, 1996, 31 (05) :288-293