Characterization of autoantibodies from patients with Goodpasture's disease using a resonant mirror biosensor

被引:13
作者
Dougan, T [1 ]
Levy, JB [1 ]
Salama, A [1 ]
George, AJT [1 ]
Pusey, CD [1 ]
机构
[1] Hammersmith Hosp, Imperial Coll, Fac Med, Renal Sect, London W12 0NN, England
关键词
biosensor; antibody affinity; autoantibodies; glomerular basement membrane; Goodpasture's disease;
D O I
10.1046/j.1365-2249.2002.01867.x
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Goodpasture's disease is characterized by the binding of IgG autoantibodies to the glomerular basement membrane, leading to glomerular inflammation. The autoantigen has been identified as the noncollagenous domain of the alpha3 chain of type IV collagen (alpha3(IV)NC1). We have used the IAsys resonant mirror biosensor to analyse the extent and affinity of binding of anti-GBM antibodies from sera of patients to purified alpha3(IV) NC1. alpha3(IV) NC1 monomers were immobilized to a carboxylate cuvette, with the simultaneous use of a control well. The binding of serum from patients with Goodpasture's disease (n = 12), normal controls (n = 14) and disease controls with vasculitis (n = 14) was analysed. Antibody binding was detected in sera from all patients with Goodpasture's disease but not from controls. IAsys measurements of binding correlated with antibody levels assessed by the standardized ELISA used for clinical assays. Both ELISA and biosensor measurements showed declining antibody levels in serial serum samples from treated patients; however, the biosensor detected antibody recrudescence when ELISA remained negative. Autoantibodies from patients' serum had average affinity constants (K-d ) of 6.5 x 10(-11) M to 52.07 x 10(-10) M, as determined by an inhibition assay, indicating high affinity. Sips analysis showed that the antibody response was relatively homogeneous (values of 0.46-1). Biosensor techniques can therefore be used to detect and characterize anti-GBM antibodies in serum from patients, with high sensitivity and without need for antibody purification. This technique may be useful in diagnosis and monitoring of patients with Goodpasture's disease, and may be applicable to other autoantibody mediated diseases.
引用
收藏
页码:555 / 561
页数:7
相关论文
共 26 条
[1]   THE RESONANT MIRROR - A NOVEL OPTICAL SENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .2. APPLICATIONS [J].
BUCKLE, PE ;
DAVIES, RJ ;
KINNING, T ;
YEUNG, D ;
EDWARDS, PR ;
POLLARDKNIGHT, D ;
LOWE, CR .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :355-363
[2]   DELIVERY OF THE RIBOSOME-INACTIVATING PROTEIN, GELONIN, TO LYMPHOMA-CELLS VIA CD22 AND CD38 USING BISPECIFIC ANTIBODIES [J].
FRENCH, RR ;
PENNEY, CA ;
BROWNING, AC ;
STIRPE, F ;
GEORGE, AJT ;
GLENNIE, MJ .
BRITISH JOURNAL OF CANCER, 1995, 71 (05) :986-994
[3]   MEASUREMENTS OF THE TRUE AFFINITY CONSTANT IN SOLUTION OF ANTIGEN-ANTIBODY COMPLEXES BY ENZYME-LINKED IMMUNOSORBENT-ASSAY [J].
FRIGUET, B ;
CHAFFOTTE, AF ;
DJAVADIOHANIANCE, L ;
GOLDBERG, ME .
JOURNAL OF IMMUNOLOGICAL METHODS, 1985, 77 (02) :305-319
[4]  
George A.J.T., 1995, TUMOUR TARGETING, V1, P245
[5]   MEASUREMENT OF KINETIC BINDING CONSTANTS OF A PANEL OF ANTI-SAPORIN ANTIBODIES USING A RESONANT MIRROR BIOSENSOR [J].
GEORGE, AJT ;
FRENCH, RR ;
GLENNIE, MJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 183 (01) :51-63
[6]   Kinetics of biomolecular interactions [J].
George, AJT ;
Gallop, JL ;
Rashid, M .
EXPERT OPINION ON THERAPEUTIC PATENTS, 1997, 7 (09) :947-963
[7]  
GEORGE AJT, 1999, INT J BIOCHROMATOGR, V4, P187
[8]  
JONSSON U, 1991, BIOTECHNIQUES, V11, P620
[9]  
KARLSSON R, 1997, PRINCIPLES PRACTICE, P99
[10]  
Katbamna I, 1995, J Clin Lab Immunol, V47, P11