A conductometric detector for capillary separations

被引:22
作者
Muller, D
Jelinek, I
Opekar, F
Stulik, K
机构
[1] UNESCO Lab. of Environ. Electrochem., Department of Analytical Chemistry, Charles University, CZ-128 40 Prague 2
关键词
conductometry; detection; capillary electrophoresis; capillary HPLC;
D O I
10.1002/elan.1140080804
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple electrochemical cell has been constructed For conductometric detection in capillary electrophoresis or HPLC. A platinum ring electrode is chemically deposited at the capillary end and the other electrode, a platinum wire, is immersed, together with the capillary, in a vessel containing the running buffer or the mobile phase used. The cell has been tested on a model system and its operational parameters have been discussed, The measurement is very sensitive (a limit of determination of ca. 3 x 10(-9) M for potassium ions) and the detector response is rapid, comparable with that of the UV photometric detector. The dynamic range is wide (at least five concentration decades) but is nonlinear at high concentrations.
引用
收藏
页码:722 / 725
页数:4
相关论文
共 14 条
[1]  
[Anonymous], 1987, ELECTROANALYTICAL ME
[2]   DETERMINATION OF CATIONS AND ANIONS BY CAPILLARY ELECTROPHORESIS COMBINED WITH SUPPRESSED CONDUCTIVITY DETECTION [J].
AVDALOVIC, N ;
POHL, CA ;
ROCKLIN, RD ;
STILLIAN, JR .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :1470-1475
[3]   ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS [J].
EWING, AG ;
MESAROS, JM ;
GAVIN, PF .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :A527-A537
[4]  
HETEM MJJ, 1987, 8TH P INT S CAP CHRO, V2, P1122
[5]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[6]   USE OF AN ON-COLUMN FRIT IN CAPILLARY ZONE ELECTROPHORESIS - SAMPLE COLLECTION [J].
HUANG, XH ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :443-446
[7]   ON-COLUMN ELECTROCHEMICAL DETECTOR WITH A SINGLE GRAPHITE FIBER ELECTRODE FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY [J].
KNECHT, LA ;
GUTHRIE, EJ ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :479-482
[8]   PICOLITER CELL-VOLUME POTENTIOMETRIC DETECTOR FOR OPEN-TUBULAR COLUMN LC [J].
MANZ, A ;
SIMON, W .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (07) :326-330
[9]   IMPROVED METHOD FOR END-COLUMN AMPEROMETRIC DETECTION FOR CAPILLARY ELECTROPHORESIS [J].
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :577-581
[10]   NOVEL ION-EXCHANGE CHROMATOGRAPHIC METHOD USING CONDUCTIMETRIC DETECTION [J].
SMALL, H ;
STEVENS, TS ;
BAUMAN, WC .
ANALYTICAL CHEMISTRY, 1975, 47 (11) :1801-1809