Successful Use of Danaparoid in Two Pregnant Women With Heart Valve Prosthesis and Heparin-Induced Thrombocytopenia Type II (HIT)

被引:7
作者
Gerhardt, Andrea [1 ]
Scharf, Ruediger E. [1 ]
Zotz, Rainer B. [1 ]
机构
[1] Univ Dusseldorf, Med Ctr, Dept Haemostasis & Transfus Med, Dusseldorf, Germany
关键词
HIT type II; pregnancy; mechanical heart valve; danaparoid; MOLECULAR-WEIGHT HEPARIN; ORGARAN ORG-10172; THROMBOEMBOLISM; ANTICOAGULATION; THROMBOSIS;
D O I
10.1177/1076029608322173
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Anticoagulant therapy with heparin for the prevention of thromboembolism in pregnant women with prosthetic heart valves is associated with an increased risk to the mother and/or the fetus. A fife-threatening complication of the therapy with heparin is heparin-induced thrombocytopenia type II (HIT). danaparoid has not yet been reported to be safe and effective for this indication. This study reports on a 26-year-old woman with tricuspidal valve prosthesis and a 37-year-old woman with a St. Jude Medical mitral valve prosthesis who were anticoagulated with danaparoid during pregnancy because of HIT. Anti-Xa levels were between 0.6 and 1.2 IU/mL during pregnancy with target levels of 1.0 IU/mL. Cesarean section was performed at anti-Xa levels of 0.3 and 0.7 IU/mL One woman developed a placental hematoma at the 32nd week of gestation, which did not increase over the following week. Both patients delivered healthy boys. Heparin-induced thrombocytopenia in pregnant women with prosthetic heart valve can be successfully managed with danaparoid.
引用
收藏
页码:461 / 464
页数:4
相关论文
共 17 条
[1]
Use of antithrombotic agents during pregnancy [J].
Bates, SA ;
Greer, IA ;
Hirsh, J ;
Ginsberg, JS .
CHEST, 2004, 126 (03) :627S-644S
[2]
Anticoagulation of pregnant women with mechanical heart valves -: A systematic review of the literature [J].
Chan, WS ;
Anand, S ;
Ginsberg, JS .
ARCHIVES OF INTERNAL MEDICINE, 2000, 160 (02) :191-196
[3]
Prospective randomised open-label comparison of danaparoid with dextran 70 in the treatment of heparin-induced thrombocytopaenia with thrombosis - A clinical outcome study [J].
Chong, BH ;
Gallus, AS ;
Cade, JF ;
Magnani, H ;
Manoharan, A ;
Oldmeadow, M ;
Arthur, C ;
Rickard, K ;
Gallo, J ;
Lloyd, J ;
Seshadri, P ;
Chesterman, CN .
THROMBOSIS AND HAEMOSTASIS, 2001, 86 (05) :1170-1175
[4]
DANHOF M, 1992, HAEMOSTASIS, V22, P73
[5]
DEVALK HW, 1995, ANN INTERN MED, V123, P1
[6]
Low-molecular-weight heparin for prosthetic heart valves: Treatment failure [J].
Lev-Ran, O ;
Kramer, A ;
Gurevitch, J ;
Shapira, I ;
Mohr, R .
ANNALS OF THORACIC SURGERY, 2000, 69 (01) :264-265
[7]
Anticoagulation for prosthetic heart valves during pregnancy: is low-molecular-weight heparin an alternative? [J].
Leyh, RG ;
Fischer, S ;
Ruhparwar, A ;
Haverich, A .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (03) :577-579
[8]
Treatment of 51 pregnancies with danaparoid because of heparin intolerance [J].
Lindhoff-Last, E ;
Kreutzenbeck, HJ ;
Magnani, HN .
THROMBOSIS AND HAEMOSTASIS, 2005, 93 (01) :63-69
[9]
Heparin-induced thrombocytopenia (HIT) - A report of 1,478 clinical outcomes of patients treated with danaparoid (Orgaran) from 1982 to mid-2004 [J].
Magnani, Harry N. ;
Gallus, Alex .
THROMBOSIS AND HAEMOSTASIS, 2006, 95 (06) :967-981
[10]
MAGNANI HN, 1993, THROMB HAEMOSTASIS, V70, P554