Thermal and SAR characterization of multielement dual concentric conductor microwave applicators for hyperthermia, a theoretical investigation

被引:39
作者
Rossetto, F [1 ]
Diederich, CJ [1 ]
Stauffer, PR [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
microwave array applicator; superficial hyperthermia; power deposition; thermal distribution; finite difference time domain (FDTD) analysis;
D O I
10.1118/1.598937
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Six aperture array dual concentric conductor (DCO) microwave hyperthermia applicators were studied using theoretical models to characterize power deposition (SAR) and steady state temperature distributions in perfused tissue. SAR patterns were calculated using the finite difference time domain (FDTD) numerical method, and were used as input to a finite difference thermal modeling program based on the Pennes Bio-Heat Equation in order to calculate corresponding temperature distributions. Numerous array configurations were investigated including the use of different size DCC apertures (2, 3, and 4 cm), different spacing between apertures (1.0-2.0 cm), and different water bolus thicknesses (5-15 mm). Thermal simulations were repeated using blood perfusion values ranging from 0.5 to 5 kg/m(3) s. Results demonstrate the ability of DCC array applicators to effectively and uniformly heat tissue down to a depth of 7.5-10 mm below the skin surface for a large number of different combinations of DCC element size, spacing, and water bolus thickness. Results also reveal the close correlation between SAR patterns and corresponding temperature distributions, verifying that design studies of the applicator can be performed confidently by analysis of SAR, from which the thermal behavior can be estimated. These simulations are useful in the design optimization of large microwave DCC array applicators for superficial tissue heating and for identifying appropriate aperture spacing and bolus thickness parameters for different size DCC aperture arrays and tissue blood perfusion conditions. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:745 / 753
页数:9
相关论文
共 33 条
[1]   RECENT DEVELOPMENTS IN MODELING HEAT-TRANSFER IN BLOOD-PERFUSED TISSUES [J].
ARKIN, H ;
XU, LX ;
HOLMES, KR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (02) :97-107
[2]   FDTD SIMULATIONS OF CLINI-THERM APPLICATORS ON INHOMOGENEOUS PLANAR TISSUE MODELS [J].
CHAN, KW ;
MCDOUGALL, JA ;
CHOU, CK .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1995, 11 (06) :809-820
[3]  
Chato J., 1990, Thermal Dosimetry and Treatment Planning (Clinical Thermology), P1
[4]   EVALUATION OF MICROWAVE HYPERTHERMIA APPLICATORS [J].
CHOU, CK .
BIOELECTROMAGNETICS, 1992, 13 (06) :581-597
[5]  
DEWHIRST MW, 1984, CANCER RES, V44, P43
[6]   Ultrasound technology for hyperthermia [J].
Diederich, CJ ;
Hynynen, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (06) :871-887
[7]   PRECLINICAL EVALUATION OF A MICROWAVE PLANAR ARRAY APPLICATOR FOR SUPERFICIAL HYPERTHERMIA [J].
DIEDERICH, CJ ;
STAUFFER, PR .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1993, 9 (02) :227-246
[8]  
Handelsman J, 1990, METHODS EXTERNAL HYP, P1
[9]   Efficacy of adjuvant hyperthermia in the treatment of superficial recurrent breast cancer: Confirmation and future directions [J].
Kapp, DS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05) :1117-1121
[10]   CUMULATIVE MINUTES OF ISOEFFECTIVE HYPERTHERMIA WITH T90=43-DEGREES-C IS THE TREATMENT PARAMETER MOST PREDICTIVE FOR OUTCOME IN PATIENTS WITH METASTATIC ADENOCARCINOMA OF THE BREAST AND SINGLE TUMOR NODULES PER TREATMENT FIELD [J].
KAPP, DS ;
COX, RS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 :315-316