Applicability and variability of liver stiffness measurements according to probe position

被引:27
作者
Ingiliz, Patrick [1 ]
Chhay, Kim Pav [1 ]
Munteanu, Mona [2 ]
Lebray, Pascal [1 ]
Ngo, Yen [1 ]
Roulot, Dominique
Benhamou, Yves [1 ]
Thabut, Dominique [1 ,3 ]
Ratziu, Vlad [1 ]
Poynard, Thierry [1 ]
机构
[1] Grp Hosp Pitie Salpetriere, AP HP, Hepatol Dept, F-75651 Paris 13, France
[2] BioPredictive, F-75007 Paris, France
[3] Hop Avicenne, AP HP, Hepatol Dept, F-93000 Bobigny, France
关键词
Fibroscan; Fibrotest; Liver fibrosis; Variability; Concordance; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; BIOMARKERS FIBROTEST; FIBROSIS; DIAGNOSIS; BIOPSY; PERFORMANCE; CIRRHOSIS; ACCURACY; ACTITEST;
D O I
10.3748/wjg.15.3398
中图分类号
R57 [消化系及腹部疾病];
学科分类号
100201 [内科学];
摘要
AIM: To investigate the liver stiffness measurement (LSM) applicability and variability with reference to three probe positions according to the region of liver biopsy. METHODS: The applicability for LSM was defined as at least 10 valid measurements with a success rate greater than 60% and an interquartile range/median LSM < 30%. The LSM variability compared the inter-position concordance and the concordance with FibroTest. RESULTS: Four hundred and forty two consecutive patients were included. The applicability of the anterior position (81%) was significantly higher than that of the reference (69%) and lower positions (68%), (both P = 0.0001). There was a significant difference (0.5 kPa, 95% CI 0.13-0.89; P < 0.0001) between mean LSM estimated at the reference position (9.3 kPa) vs the anterior position (8.8 kPa). Discordance between positions was associated with thoracic fold (P = 0.008). The discordance rate between the reference position result and FibroTest was higher when the 7.1 kPa cutoff was used to define advanced fibrosis instead of 8.8 kPa (33.6% vs 23.5%, P = 0.03). CONCLUSION: The anterior position of the probe should be the first choice for LSM using Fibroscan, as it has a higher applicability without higher variability compared to the usual liver biopsy position. (C) 2009 The WJG Press and Baishideng. All rights reserved.
引用
收藏
页码:3398 / 3404
页数:7
相关论文
共 27 条
[1]
Diagnosing fibrosis in hepatitis C: Is the pendulum swinging from biopsy to blood tests? [J].
Afdhal, NH .
HEPATOLOGY, 2003, 37 (05) :972-974
[2]
[Anonymous], NCSS 2007 USER GUIDE
[3]
[Anonymous], BIOMETRICS
[4]
An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[5]
Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[6]
Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].
Castéra, L ;
Vergniol, J ;
Foucher, J ;
Le Bail, B ;
Chanteloup, E ;
Haaser, M ;
Darriet, M ;
Couzigou, P ;
De Lédinghen, V .
GASTROENTEROLOGY, 2005, 128 (02) :343-350
[7]
Evolving practices of non-invasive markers of liver fibrosis in patients with chronic hepatitis C in France: Time for new guidelines? [J].
Castera, Laurent ;
Denis, Jacques ;
Babany, Gerard ;
Roudot-Thoraval, Francoise .
JOURNAL OF HEPATOLOGY, 2007, 46 (03) :528-+
[8]
Transient elastography: a new surrogate marker of liver fibrosis influenced by major changes of transaminases [J].
Coco, B. ;
Oliveri, F. ;
Maina, A. M. ;
Ciccorossi, P. ;
Sacco, R. ;
Colombatto, P. ;
Bonino, F. ;
Brunetto, M. R. .
JOURNAL OF VIRAL HEPATITIS, 2007, 14 (05) :360-369
[9]
Diagnosis of cirrhosis by transient elastography (FibroScan):: a prospective study [J].
Foucher, J ;
Chanteloup, E ;
Vergniol, J ;
Castéra, L ;
Le Bail, B ;
Adhoute, X ;
Bertet, J ;
Couzigou, P ;
de Lédinghen, V .
GUT, 2006, 55 (03) :403-408
[10]
Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease [J].
Fraquelli, Mirella ;
Rigamonti, Cristina ;
Casazza, Giovanni ;
Conte, Dario ;
Donato, Maria Francesca ;
Ronchi, Guido ;
Colombo, Massimo .
GUT, 2007, 56 (07) :968-973