Experimental investigation of a two-phase ejector cycle suitable for use with low-pressure refrigerants R134a and R1234yf

被引:96
作者
Lawrence, Neal [1 ]
Elbel, Stefan [1 ]
机构
[1] Univ Illinois, Dept Mech Sci & Engn, Air Conditioning & Refrigerat Ctr, Urbana, IL 61801 USA
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2014年 / 38卷
关键词
Ejector; Expansion work recovery; Cycle comparison; Coefficient of performance; Evaporator design; PERFORMANCE; IMPROVEMENT;
D O I
10.1016/j.ijrefrig.2013.08.009
中图分类号
O414.1 [热力学];
学科分类号
070201 [理论物理];
摘要
This paper presents the results of an experimental investigation in which the performance of the low-pressure fluids R134a and R1234yf was compared between a two-phase ejector cycle and expansion valve cycles. An alternate two-phase ejector cycle, in which the pressure lift provided by the ejector was utilized in order to provide multiple evaporation temperatures, was constructed and tested. The experimental results show that ejectors designed for low-pressure fluids were able to achieve similar but lower work recovery efficiencies compared to CO2 ejectors. When compared to a two evaporation temperature expansion valve cycle, the ejector cycle showed maximum COP improvements of 12% with R1234yf and 8% with R134a. When compared to a single evaporation temperature expansion valve cycle, the ejector cycle showed maximum COP improvements of 6% with R1234yf and 5% with R134a. The effect of evaporator design on ejector cycle COP improvement was also demonstrated experimentally. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:310 / 322
页数:13
相关论文
共 20 条
[1]
American Society of Heating Refrigerating and Air-conditioning Engineers (ASHRAE), 1992, 4121987RA92 ASHRAE
[2]
Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump [J].
Banasiak, Krzysztof ;
Hafner, Armin ;
Andresen, Trond .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (06) :1617-1625
[3]
Brodie B.R., 2012, 2012011048 SAE
[4]
Butrymowicz D., 2005, IIR INT C THERM PROP, P695
[5]
Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device [J].
Disawas, S ;
Wongwises, S .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (06) :587-594
[6]
Flash gas bypass for improving the performance of transcritical R744 systems that use microchannel evaporators [J].
Elbel, S ;
Hrnjak, P .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (07) :724-735
[7]
Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation [J].
Elbel, Stefan ;
Hrnjak, Pega .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03) :411-422
[8]
Gay N. H., 1931, US Patent, Patent No. 1836318
[9]
Harrell G.S., 1995, P INT EN CONV ENG C
[10]
Klein S.A., 2012, ENG EQUATION SOLVER