Nosocomial malaria from contamination of a multidose heparin container with blood

被引:20
作者
Al-Saigul, AM
Fontaine, RE
Haddad, Q
机构
[1] Minist Hlth, Saudi Arabian Field Epidemiol Training Program, Riyadh, Saudi Arabia
[2] Ctr Dis Control, Div Int Hlth, Epidemiol Program Off, Atlanta, GA 30333 USA
[3] Ctr Prevent, Atlanta, GA 30333 USA
[4] Secur Forces Hosp, Riyadh, Saudi Arabia
关键词
D O I
10.1086/501765
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A girl developed Plasmodium falciparum malaria in Riyadh, Saudi Arabia, a non-malarious area. Twelve to 18 days before onset, she had been hospitalized for asthma on the same ward as three malaria patients. The only link between the malaria patients and the asthma patient was a multidose heparin container used to fill syringes for use on heparin locks and intravenous devices. Contamination of the heparin with blood occurred on at least one occasion when a needle had been left in place through the septum of this container and was used to refill a used syringe.
引用
收藏
页码:329 / 330
页数:2
相关论文
共 7 条
[1]   Plasmodium falciparum malaria transmitted in hospital through heparin locks [J].
Abulrahi, HA ;
Bohlega, EA ;
Fontaine, RE ;
AlSeghayer, SM ;
AlRuwais, AA .
LANCET, 1997, 349 (9044) :23-25
[2]  
ALABDULLATIF Z, 1996, SAUDI EPIDEMIOLOGY B, V3, P17
[3]   A nosocomial outbreak of malaria associated with contaminated catheters and contrast medium of a computed tomographic scanner [J].
Chen, KT ;
Chen, CJ ;
Chang, PY ;
Morse, DL .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1999, 20 (01) :22-25
[4]  
ISAACSON M, 1989, B WORLD HEALTH ORGAN, V67, P737
[5]  
LETTAU LA, 1991, INFECT CONT HOSP EP, V12, P111, DOI 10.1086/646297
[6]  
NAVARRO P, 1987, Boletin de la Oficina Sanitaria Panamericana, V102, P476
[7]  
*PUBL HLTH LAB SER, 1999, COMMUN DIS REP CDR W, V9, P123