Fracture and migration of a suprarenal inferior vena cava filter in a pregnant patient

被引:36
作者
Ganguli, Suvranu
Tham, Jacques C.
Komlos, Fabio
Rabkin, Dmitry J.
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
关键词
D O I
10.1097/01.RVI.0000236717.27681.09
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Placement of retrievable inferior vena cava (IVC) filters as prophylaxis for pulmonary embolism (PE) is an increasingly attractive option for patients who require temporary IVC filtration. However, experience thus far with retrievable filters in pregnant patients is limited. This report describes a suprarenally placed Recovery IVC filter in a pregnant woman with PE despite therapeutic anticoagulation. After failed induction of labor and uneventful cesarean section, the patient returned for filter retrieval 167 days after initial placement. Fracture and inferior migration of the filter was observed, and subsequent attempts at filter retrieval were unsuccessful.
引用
收藏
页码:1707 / 1711
页数:5
相关论文
共 11 条
[1]   Initial experience in humans with a new retrievable inferior vena cava filter [J].
Asch, MR .
RADIOLOGY, 2002, 225 (03) :835-844
[2]   Inferior vena caval filters: Review of a 26-year single-center clinical experience [J].
Athanasoulis, CA ;
Kaufman, JA ;
Halpern, EF ;
Waltman, AC ;
Geller, SC ;
Fan, CM .
RADIOLOGY, 2000, 216 (01) :54-66
[3]  
BALLEW KA, 1995, CLIN CHEST MED, V16, P295
[4]   Placement of a temporary vena cava filter during labor [J].
Clark, SL ;
Blatter, DD ;
Jackson, GM .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2005, 193 (05) :1746-1747
[5]   Experience with the recovery filter as a retrievable inferior vena cava filter [J].
Grande, WJ ;
Trerotola, SO ;
Reilly, PM ;
Clark, TWI ;
Soulen, MC ;
Patel, A ;
Shlansky-Goldberg, RD ;
Tuite, CM ;
Solomon, JA ;
Mondschein, JI ;
Fitzpatrick, MK ;
Stavropoulos, SW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (09) :1189-1193
[6]   Suprarenal filter placement [J].
Greenfield, LJ ;
Proctor, MC .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (03) :432-438
[7]   Difficult retrieval of a recovery IVC filter [J].
Hagspiel, KD ;
Leung, DA ;
Aladdin, M ;
Spinosa, DJ ;
Matsumoto, AH ;
Angle, JF .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (06) :645-647
[8]   Experience of temporary inferior vena cava filters inserted in the perinatal period to prevent pulmonary embolism in pregnant women with deep vein thrombosis [J].
Kawamata, K ;
Chiba, Y ;
Tanaka, R ;
Higashi, M ;
Nishigami, K .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (04) :652-656
[9]   Update on inferior vena cava filters [J].
Kinney, TB .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (04) :425-440
[10]   Suprarenal vena caval filter placement: Follow-up of four filter types in 22 patients [J].
Matchett, WJ ;
Jones, MP ;
McFarland, DR ;
Ferris, EJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (04) :588-593