Mechanical analysis of a rodent segmental bone defect model: The effects of internal fixation and implant stiffness on load transfer

被引:33
作者
Yavari, S. Amin [1 ]
van der Stok, J. [2 ]
Ahmadi, S. M. [1 ]
Wauthle, R. [3 ,4 ]
Schrooten, J. [5 ]
Weinans, H. [1 ,6 ,7 ]
Zadpoor, A. A. [1 ]
机构
[1] Delft Univ Technol, Fac Mech Maritime & Mat Engn, TU Delft, NL-2628 CD Delft, Netherlands
[2] Erasmus Univ, Rotterdam Med Ctr, Dept Orthopaed, Orthopaed Res Lab, Rotterdam, Netherlands
[3] Katholieke Univ Leuven, Dept Mech Engn, Sect Prod Engn Machine Design & Automat PMA, B-3001 Leuven, Belgium
[4] LayerWise NV, B-3001 Leuven, Belgium
[5] Katholieke Univ Leuven, Dept Met & Mat Engn, B-3001 Heverlee, Belgium
[6] UMC Utrecht, Dept Orthoped, NL-3584 CX Utrecht, Netherlands
[7] UMC Utrecht, Dept Rheumatol, NL-3584 CX Utrecht, Netherlands
关键词
Segmental bone defect model; Animal models; Implant stiffness; Load transfer; Variability; ANIMAL-MODELS; IN-VIVO; GRAFT; BIOMATERIALS; SCAFFOLDS; REGENERATION; AUTOGRAFT; DELIVERY; FATIGUE; SURFACE;
D O I
10.1016/j.jbiomech.2014.05.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Segmental bone defect animal models are often used for evaluating the bone regeneration performance of bone substituting biomaterials. Since bone regeneration is dependent on mechanical loading, it is important to determine mechanical load transfer after stabilization of the defect and to study the effects of biomaterial stiffness on the transmitted load. In this study, we assess the mechanical load transmitted over a 6 mm femur defect that is stabilized with an internal PEEK fixation plate. Subsequently, three types of selective laser melted porous titanium implants with different stiffness values were used to graft the defect (five specimens per group). In one additional group, the defect was left empty. Micro strain gauges were used to measure strain values at four different locations of the fixation plate during external loading on the femoral head. The load sharing between the fixation plate and titanium implant was highly variable with standard deviations of measured strain values between 31 and 93% of the mean values. As a consequence, no significant differences were measured between the forces transmitted through the titanium implants with different elastic moduli. Only some non-significant trends were observed in the mean strain values that, consistent with the results of a previous finite element study, implied the force transmitted through the implant increases with the implant stiffness. The applied internal fixation method does not standardize mechanical loading over the defect to enable detecting small differences in bone regeneration performances of bone substituting biomaterials. In conclusion, the fixation method requires further optimization to reduce the effects of the operative procedure and make the mechanical loading more consistent and improve the overall sensitivity of this rat femur defect model. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2700 / 2708
页数:9
相关论文
共 51 条
[1]
Bauer TW, 2000, CLIN ORTHOP RELAT R, P10
[2]
Bendele A. M., 2001, Journal of Musculoskeletal & Neuronal Interactions, V1, P363
[3]
Betz RR, 2002, ORTHOPEDICS, V25, pS561
[4]
Image-based musculoskeletal modeling: Applications, advances, and future opportunities [J].
Blemker, Silvia S. ;
Asakawa, Deanna S. ;
Gold, Garry E. ;
Delp, Scott L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) :441-451
[5]
Resorbable biomaterials as bone graft substitutes [J].
Bohner, Marc .
MATERIALS TODAY, 2010, 13 (1-2) :24-30
[6]
Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing [J].
Campoli, G. ;
Borleffs, M. S. ;
Yavari, S. Amin ;
Wauthle, R. ;
Weinans, H. ;
Zadpoor, A. A. .
MATERIALS & DESIGN, 2013, 49 :957-965
[7]
Computational load estimation of the femur [J].
Campoli, Gianni ;
Weinans, Harrie ;
Zadpoor, Amir Abbas .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 10 :108-119
[8]
A tissue engineering approach to bone repair in large animal models and in clinical practice [J].
Cancedda, Ranieri ;
Giannoni, Paolo ;
Mastrogiacomo, Maddalena .
BIOMATERIALS, 2007, 28 (29) :4240-4250
[9]
Synthetic bone scaffolds and fracture repair [J].
Carson, Joshua S. ;
Bostrom, Mathias P. G. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 :S33-S37
[10]
Chu CR, 2010, TISSUE ENG PART B-RE, V16, P105, DOI [10.1089/ten.teb.2009.0452, 10.1089/ten.TEB.2009.0452]