Cognitive, cardiac, and physiological safety studies in ultra high field magnetic resonance imaging

被引:121
作者
Kangarlu, A
Burgess, RE
Zhu, H
Nakayama, T
Hamlin, RL
Abduljalil, AM
Robitaille, PML
机构
[1] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Vet Biosci, Columbus, OH 43210 USA
关键词
safety; human; cardiac; high field;
D O I
10.1016/S0730-725X(99)00086-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A systematic analysis of the effect of an 8.0 tesla static magnetic field on physiological and/or cognitive function is presented in the normal volunteer and in the swine. A study of ten human subjects revealed no evidence of detectable changes in body temperature, heart rate, respiratory rate, systolic pressure, and diastolic blood pressure after 1 hour of exposure. In addition, no cognitive changes were detected. Important ECG changes were noted which were related both to the position of the subject in the magnet and to the absolute strength of the magnetic field. As such, the ECG tracing at 8 tesla was not diagnostically useful. Nonetheless, all subjects exhibited normal ECG readings both before and following exposure to the 8 tesla field. Cardiac function was also examined in detail in the swine. No significant changes in body temperature, heart rate, left ventricular pressure, left ventricular end diastollic pressure, time rate of change of left ventricular pressure, myocardial stiffness index, cardiac output, systolic volume, troponin, and potassium levels could be detected following 3 h of exposure to a field strength of 8.0 tesla. It is concluded that no short term cardiac or cognitive effects are observed following significant exposure to a magnetic field of up to 8.0 tesla. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1407 / 1416
页数:10
相关论文
共 15 条
[1]   Acquisition of human multislice MR images at 8 Tesla [J].
Abduljalil, AM ;
Kangarlu, A ;
Zhang, XL ;
Burgess, RE ;
Robitaille, PML .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) :335-340
[2]   POWER DEPOSITION IN WHOLE-BODY NMR IMAGING [J].
BOTTOMLEY, PA ;
EDELSTEIN, WA .
MEDICAL PHYSICS, 1981, 8 (04) :510-512
[3]   THRESHOLDS FOR PHYSIOLOGICAL-EFFECTS DUE TO RF AND MAGNETIC-FIELDS USED IN NMR IMAGING [J].
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2821-2825
[4]   ALTERATIONS IN THE RAT ELECTROCARDIOGRAM INDUCED BY STATIONARY MAGNETIC-FIELDS [J].
GAFFEY, CT ;
TENFORDE, TS .
BIOELECTROMAGNETICS, 1981, 2 (04) :357-370
[5]   THE FIELD-DEPENDENCE OF NMR IMAGING .2. ARGUMENTS CONCERNING AN OPTIMAL FIELD-STRENGTH [J].
HOULT, DI ;
CHEN, CN ;
SANK, VJ .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :730-746
[6]  
KANGARLU A, 1998, WORKSH NEW INS SAF C, P26
[7]   MAGNETOHYDRODYNAMICS OF BLOOD-FLOW [J].
KELTNER, JR ;
ROOS, MS ;
BRAKEMAN, PR ;
BUDINGER, TF .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (01) :139-149
[8]  
Kinouchi Y, 1996, BIOELECTROMAGNETICS, V17, P21, DOI 10.1002/(SICI)1521-186X(1996)17:1<21::AID-BEM3>3.0.CO
[9]  
2-8
[10]   AN ALTERNATING FIELD INDUCTION FLOW METER OF HIGH SENSITIVITY [J].
KOLIN, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1945, 16 (05) :109-116