A microdevice with integrated liquid junction for facile peptide and protein analysis by capillary electrophoresis/electrospray mass spectrometry

被引:156
作者
Zhang, BL
Foret, F [1 ]
Karger, BL
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac991150z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel microfabricated device was implemented for facile coupling of capillary electrophoresis with mass spectrometry (CE/MS), The device was constructed from glass wafers using standard photolithographic/wet chemical etching methods. The design integrated (a) sample inlet ports, (b) the separation channel, (c) a liquid junction, and (d) a guiding channel for the insertion of the electrospray capillary, which was enclosed in a miniaturized subatmospheric electrospray chamber of an ion trap MS. The replaceable electrospray capillary was precisely aligned with the exit of the separation channel by a microfabricated guiding channel. No glue was necessary to seal the electrospray capillary. This design allowed simple and fast replacement of either the microdevice or the electrospray capillary. The performance of the device was tested for CE/MS of peptides, proteins, and protein tryptic digests. On-line tandem mass spectrometry was used for the structure identification of the protein digest products. High-efficiency/high-resolution separations could be obtained on a longer channel (11 cm on-chip) microdevice, and fast separations (under 50 s) were achieved with a short (4.5 cm on-chip) separation channel. In the experiments, both electrokinetic and pressure injections were used. The separation efficiency was comparable to that obtained from conventional capillary electrophoresis.
引用
收藏
页码:1015 / 1022
页数:8
相关论文
共 37 条
[1]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[2]   Bioanalytic applications of mass spectrometry [J].
Costello, CE .
CURRENT OPINION IN BIOTECHNOLOGY, 1999, 10 (01) :22-28
[3]   Dispersion sources for compact geometries on microchips [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3781-3789
[4]  
Desai A, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P927, DOI 10.1109/SENSOR.1997.635254
[5]   Microreactors for chemical synthesis [J].
DeWitt, SH .
CURRENT OPINION IN CHEMICAL BIOLOGY, 1999, 3 (03) :350-356
[6]  
Effenhauser CS, 1998, TOP CURR CHEM, V194, P51
[7]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160
[8]   TRACE ANALYSIS OF PROTEINS BY CAPILLARY ZONE ELECTROPHORESIS WITH ON-COLUMN TRANSIENT ISOTACHOPHORETIC PRECONCENTRATION [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
ELECTROPHORESIS, 1993, 14 (5-6) :417-428
[9]  
FORET F, 1996, 44 ASMS C MASS SPECT
[10]  
FORET F, IN PRESS ELECTROPHOR