Experimental evaluation of wind turbines maximum power point tracking controllers

被引:106
作者
Camblong, H.
de Alegria, I. Martinez
Rodriguez, M.
Abad, G.
机构
[1] LIPSI ESTIA, F-64210 Bidart, France
[2] Univ Basque Country, Bilbao 48013, Spain
[3] EPS, Arrasate Mondragon, Spain
关键词
variable speed wind turbine; control; test bench; energetic efficiency; performance evaluation;
D O I
10.1016/j.enconman.2006.03.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
Wind energy technology has experienced important improvements this last decade. The transition from fixed speed to variable speed wind turbines has been a significant element of these improvements. It has allowed adapting the turbine rotational speed to the wind speed variations with the aim of optimizing the aerodynamic efficiency. A classic controller that has slow dynamics relative to the mechanical dynamics of the drive train is implemented in commercial wind turbines. The objective of the work related in this paper has been to evaluate the implementation, on a test bench, of a controller whose dynamics can be adjusted to be faster and to compare in particular its aerodynamic efficiency with the conventional controller. In theory, the higher dynamics of the non-classic controller has to lead to a better efficiency. A 180 kW wind turbine whose simulation model has been validated with field data is emulated on an 18 kW test bench. The emulator has also been validated. Test bench trials are a very useful step between numerical simulation and trials on the real system because they allow analyzing some phenomena that may not appear in simulations without endangering the real system. The trials on the test bench show that the non-conventional controller leads to a higher aerodynamic efficiency and that this is offset by higher mechanical torque and electric power fluctuations. Nevertheless, the amplitudes of these fluctuations are relatively low compared to their rated values. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2846 / 2858
页数:13
相关论文
共 22 条
[1]   On some of the design aspects of wind energy conversion systems [J].
Bansal, RC ;
Bhatti, TS ;
Kothari, DP .
ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (16) :2175-2187
[2]   Performance optimization for doubly fed wind power generation systems [J].
Bhowmik, S ;
Spée, R ;
Enslin, JHR .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (04) :949-958
[3]  
Bossanyi E.A, 2000, Wind Energy, V3, P149
[4]  
Camblong H., 2004, Wind Engineering, V28, P157, DOI 10.1260/0309524041211369
[5]   Robust digital control of a wind turbine for rated-speed and variable-power operation regime [J].
Camblong, H ;
Tapia, G ;
Rodríguez, M .
IEE PROCEEDINGS-CONTROL THEORY AND APPLICATIONS, 2006, 153 (01) :81-91
[6]  
CAMBLONG H, 2003, THESIS ENSAM MONDRAG
[7]  
CARDENAS R, 2001, EPE C GRAZ AUSTR
[8]  
CARDENASDOBSON R, 1996, THESIS U NOTTINGHAM
[9]  
CONNOR B, 1994, WIND ENERGY CONVERSI
[10]   Sliding mode control of wind energy systems with DOIG - Power efficiency and torsional dynamics optimization [J].
De Battista, H ;
Puleston, PF ;
Mantz, RJ ;
Christiansen, CF .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (02) :728-734