Diagnostic Accuracy and Impact of Computed Tomographic Coronary Angiography on Utilization of Invasive Coronary Angiography

被引:119
作者
Chow, Benjamin J. W. [1 ,2 ]
Abraham, Arun [1 ]
Wells, George A. [1 ]
Chen, Li [1 ]
Ruddy, Terrence D. [1 ,2 ]
Yam, Yeung [1 ]
Govas, Nayia [1 ]
Galbraith, Phoebe Diane [3 ]
Dennie, Carole [2 ]
Beanlands, Rob S. [1 ,2 ]
机构
[1] Univ Ottawa, Inst Heart, Dept Med Cardiol, Ottawa, ON K1Y 4W7, Canada
[2] Ottawa Hosp, Dept Radiol, Ottawa, ON, Canada
[3] Univ Calgary, Dept Cardiac Sci, Calgary, AB, Canada
关键词
computed tomography; coronary angiography; clinical impact; accuracy; normalcy; POSITRON-EMISSION-TOMOGRAPHY; ASSOCIATION TASK-FORCE; ARTERY-DISEASE; PRACTICE GUIDELINES; AMERICAN-COLLEGE; HIGH-RISK; PERFUSION; EXERCISE; SPECIFICITY; PREVALENCE;
D O I
10.1161/CIRCIMAGING.108.792572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Computed tomographic coronary angiography (CTA), given its high negative predictive value, is a potential gatekeeper for invasive coronary angiography (ICA). Before CTA can be further accepted into clinical practice, its impact on healthcare resources needs to be better understood. We sought to determine the clinical impact of CTA on ICA referrals, CTA accuracy, and normalcy rate. Methods and Results-To determine the impact of CTA, consecutive patients (n=7017) undergoing ICA before and after implementing a dedicated cardiac CT program were reviewed and compared with 3 other centers (n=11 508). To determine CTA accuracy, we evaluated consecutive CTA patients who underwent ICA. For normalcy rate, we identified patients with a low pretest probability for obstructive coronary artery disease. With the implementation of a cardiac CT program, the frequency of normal ICA decreased from 31.5% (1114 of 3538 patients) to 26.8% (932 of 3479 patients) (P<0.001). These findings were significantly different (P=0.003) from the 3 centers, in which normal ICAs were unchanged (30.0% [1870 of 6224 patients] to 31.0% [1642 of 5284 patients.]). CTA had excellent per-patient sensitivity (99% [CI, 95% to 100%]), positive predictive value (92% [CI, 86% to 96%]) and negative predictive value (95% [CI, 72% to 100%]). Because of referral bias., specificity (64% [CI, 44% to 81%1) was low; however, the normalcy rate of CTA was 94% (CI. 90% to 97%). After adjusting for referral bias, the adjusted sensitivity was 90% (CI, 89% to 9 1 %) and the adjusted specificity was 95% (CI, 94% to 96%), with positive and negative predictive values of 92% (CI, 91% to 93%) and 93% (CI 92% to 94%), respectively. Conclusion-The clinical implementation of CTA appears to positively impact ICA by reducing the frequency of normal ICA. The operating characteristics of CTA support its potential role Lis a tool useful in ruling out obstructive coronary artery disease. (Circ Cardiovasc Imaging. 2009;2:16-23.)
引用
收藏
页码:16 / 23
页数:8
相关论文
共 26 条
[1]   Adenosine technetium-99m sestamibi myocardial perfusion SPECT in women: Diagnostic efficacy in detection of coronary artery disease [J].
Amanullah, AM ;
Kiat, H ;
Friedman, JD ;
Berman, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (04) :803-809
[2]   Accuracy of 99mTc-tetrofosmin myocardial tomography in the evaluation of coronary artery disease [J].
Azzarelli, S ;
Galassi, AR ;
Foti, R ;
Mammana, C ;
Musumeci, S ;
Giuffrida, G ;
Tamburino, C .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (02) :183-189
[3]   DOBUTAMINE STRESS ECHOCARDIOGRAPHY - PREVALENCE OF A NONISCHEMIC RESPONSE IN A LOW-RISK POPULATION [J].
BACH, DS ;
HEPNER, A ;
MARCOVITZ, PA ;
ARMSTRONG, WF .
AMERICAN HEART JOURNAL, 1993, 125 (05) :1257-1261
[4]   CCS/CAR/CANM/CNCS/CanSCMR joint position statement on advanced noninvasive cardiac imaging using positron emission tomography, magnetic resonance imaging and multidetector computed tomographic angiography in the diagnosis and evaluation of ischemic heart disease - executive summary [J].
Beanlands, R. S. B. ;
Chow, B. J. W. ;
Dick, A. ;
Friedrich, M. G. ;
Gulenchyn, K. Y. ;
Kiess, M. ;
Leong-Poi, H. ;
Miller, R. M. ;
Nichol, G. ;
Freeman, M. ;
Bogaty, P. ;
Honos, G. ;
Hudon, G. ;
Wisenberg, G. ;
Van Berkom, J. ;
Williams, K. ;
Yoshinaga, K. ;
Graham, J. .
CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (02) :107-119
[5]   SEPARATE ACQUISITION REST THALLIUM-201/STRESS TC-99M SESTAMIBI DUAL-ISOTOPE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A CLINICAL VALIDATION-STUDY [J].
BERMAN, DS ;
KIAT, H ;
FRIEDMAN, JD ;
WANG, FP ;
VANTRAIN, K ;
MATZER, L ;
MADDAHI, J ;
GERMANO, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1455-1464
[6]   ANGIOGRAPHIC PREVALENCE OF HIGH-RISK CORONARY-ARTERY DISEASE IN PATIENT SUBSETS (CASS) [J].
CHAITMAN, BR ;
BOURASSA, MG ;
DAVIS, K ;
ROGERS, WJ ;
TYRAS, DH ;
BERGER, R ;
KENNEDY, JW ;
FISHER, L ;
JUDKINS, MP ;
MOCK, MB ;
KILLIP, T .
CIRCULATION, 1981, 64 (02) :360-367
[7]   Comparison of computed tomographic angiography versus rubidium-82 positron emission tomography for the detection of patients with anatomical coronary artery disease [J].
Chow, Benjamin J. W. ;
Dennie, Carole ;
Hoffmann, Udo ;
So, Derek ;
Dekemp, Robert A. ;
Ruddy, Terrence D. ;
Beanlands, Rob S. .
CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (10) :801-807
[8]  
Chow BJW, 2005, CAN J CARDIOL, V21, P933
[9]   New technology for noninvasive evaluation of coronary artery disease [J].
Di Carli, Marcelo F. ;
Hachamovitch, Rory .
CIRCULATION, 2007, 115 (11) :1464-1480
[10]  
Di Carli MF, 2006, J NUCL MED, V47, P1397