Antibody immobilization on functional monolayers using a quartz crystal microbalance

被引:7
作者
Aizawa, Hidenobu [1 ]
Gokita, Yasutoshi
Park, Jong-Won
Yoshimi, Yasuo
Kurosawa, Shigeru
机构
[1] Natl Inst Adv Ind Sci & Technol, Ibaraki 3058565, Japan
[2] Shibaura Inst Technol, Tokyo 1088548, Japan
[3] Univ Tokyo, Dept Mat Sci, Tokyo 1138656, Japan
关键词
anti-C-reactive protein (CRP) antibody; CRP detection; functional monolayer; immunosensor; quartz crystal microbalance (QCM);
D O I
10.1109/JSEN.2006.881368
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper evaluated immobilization of anti-C-reactive protein (CRP) monoclonal antibody on a quartz crystal microbalance (QCM) when 2-aminoethanethiol (AET), 4,4'-dithiodibutyric acid (DDA), and 11-mercaptoundecanoic acid (MUA) were deposited on the gold surface of QCM. In all monolayers, anti-CRP antibodies were immobilized such as Langmuir types because it had been introduced with a corresponding active group. According to the Langmuir isotherm equation a(max), the maximum immobilized amounts of anti-CRP antibody were 4.27, 2.72, and 3.74 pmol/cm(2), respectively. Although the immobilized amount of anti-CRP antibody was highest on the AET monolayer, the amount of antigen-antibody binding between the anti-CRP antibody and the CRP was highest on the MUA monolayer. CRP was detected from negative to positive levels when the calibration curve was achieved using MUA monolayer.
引用
收藏
页码:1052 / 1056
页数:5
相关论文
共 16 条
  • [1] Piezoelectric quartz crystal biosensors
    Bunde, RL
    Jarvi, EJ
    Rosentreter, JJ
    [J]. TALANTA, 1998, 46 (06) : 1223 - 1236
  • [2] SELF-ASSEMBLED MONOLAYER FILMS OF C(60) ON CYSTEAMINE-MODIFIED GOLD
    CALDWELL, WB
    CHEN, K
    MIRKIN, CA
    BABINEC, SJ
    [J]. LANGMUIR, 1993, 9 (08) : 1945 - 1947
  • [3] CONTINUOUS LIQUID-PHASE PIEZOELECTRIC BIOSENSOR FOR KINETIC IMMUNOASSAYS
    DAVIS, KA
    LEARY, TR
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (11) : 1227 - 1230
  • [4] Surface engineering: Optimization of antigen presentation in self-assembled monolayers
    Duschl, C
    SevinLandais, AF
    Vogel, H
    [J]. BIOPHYSICAL JOURNAL, 1996, 70 (04) : 1985 - 1995
  • [5] Compositional mapping of self-assembled monolayers derivatized within microfluidic networks
    Hinder, SJ
    Connell, SD
    Davies, MC
    Roberts, CJ
    Tendler, SJB
    Williams, PM
    [J]. LANGMUIR, 2002, 18 (08) : 3151 - 3158
  • [6] Latex piezoelectric immunoassay: Analysis of C-reactive protein in human serum
    Kurosawa, S
    Aizawa, H
    Yoshimoto, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (05) : 1256 - 1258
  • [7] Kurosawa S, 1997, ACS SYM SER, V657, P185
  • [8] Characterization of a self-assembled monolayer of thiol on a gold surface and the fabrication of a biosensor chip based on surface plasmon resonance for detecting anti-GAD antibody
    Lee, JW
    Sim, SJ
    Cho, SM
    Lee, J
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (07) : 1422 - 1427
  • [9] Immunosensors - principles and applications to clinical chemistry
    Luppa, PB
    Sokoll, LJ
    Chan, DW
    [J]. CLINICA CHIMICA ACTA, 2001, 314 (1-2) : 1 - 26
  • [10] Immunosensors for pesticide determination in natural waters
    Mallat, E
    Barceló, D
    Barzen, C
    Gauglitz, G
    Abuknesha, R
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) : 124 - 132