Biomechanical analysis of multilevel fixation methods in the lumbar spine

被引:59
作者
Glazer, PA [1 ]
Colliou, O [1 ]
Klisch, SM [1 ]
Bradford, DS [1 ]
Bueff, HU [1 ]
Lotz, JC [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT ORTHOPAED SURG,ORTHOPAED BIOENGN LAB,SAN FRANCISCO,CA 94143
关键词
interbody fusion; lumbar fixation; spinal instrumentation;
D O I
10.1097/00007632-199701150-00008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design, The authors measured and compared the stiffness of cadaveric,lumbar spines stabilized with several anterior interbody fusion devices. The information obtained provides a foundation for determining how methods of anterior lumbar fixation can maximize rigidity and promote development of bony fusion. Objectives. To compare the utility of three-anterior spinal instrumentation systems for Stabilizing the lumbar spine. Summary of Background Data. Anterior spinal instrumentation is used to prevent progressive spinal deformity and maintain correction after spinal fusion surgery. Newer instrumentation systems-developed for anterior interbody fusions can be inserted by minimally, invasive procedures. The-stability of these systems has not been tested adequately in human cadaveric specimens. Methods. Fusion constructs were evaluated in 12 human cadaveric specimens sequentially loaded in axial compression and torsion, flexion and extension, and lateral bending. The fusion constructs used were 1) two anterior bilateral threaded interbody fusion devices, 2) lateral hollow interbody screws (Texas Scottish Rite Hospital-B screws), and 3) femoral allograft and conventional anterior Texas Scottish Rite Hospital instrumentation. Results. The construct with Texas Scottish Rite Hospital-B screws connected by a rod produced stiffness comparable with that produced by conventional Texas Scottish Rite Hospital instrumentation with femoral ring allografts. The threaded interbody fusion-device stiffness tested in axial rotation was comparable with that achieved with Texas Scottish Rite Hospital instrumentation. Conclusions. Our data demonstrate the effectiveness of threaded interbody fusion device and the Texas Scottish Rite Hospital-B screw in immobilizing the L3-L4 and L4-L5 disc spaces. Rigidity of fixation in the lumbar spine may aid in the maintenance of lordosis.
引用
收藏
页码:171 / 182
页数:12
相关论文
共 41 条
[1]  
AARON AD, 1994, ORTHOPEDICS, V17, P41
[2]   INTERSEGMENTAL SPINAL FLEXIBILITY WITH LUMBOSACRAL INSTRUMENTATION - AN INVITRO BIOMECHANICAL INVESTIGATION [J].
ASAZUMA, T ;
STOKES, IAF ;
MORELAND, MS ;
SUZUKI, N .
SPINE, 1990, 15 (11) :1153-1158
[3]  
BAGBY GW, 1988, ORTHOPEDICS, V11, P931
[4]   ANTERIOR DECOMPRESSION AND STABILIZATION OF THORACOLUMBAR BURST FRACTURES BY THE USE OF THE SLOT-ZIELKE DEVICE [J].
BEEN, HD .
SPINE, 1991, 16 (01) :70-77
[5]  
BRIDWELL KH, 1994, SPINE, V19, P1094
[6]  
BUTTS MK, 1987, ADV BIOENGINEERING
[7]  
CLOWARD R B, 1963, Clin Orthop Relat Res, V27, P51
[9]  
CLOWARD RB, 1981, CLIN ORTHOPAEDICS, V154, P76
[10]   A MODIFIED CLOWARDS TECHNIQUE FOR ARTHRODESIS OF THE NORMAL METACARPOPHALANGEAL JOINT IN THE HORSE [J].
CRAWLEY, GR ;
GRANT, BD ;
WHITE, KK ;
BARBEE, DD ;
GALLINA, AM ;
RATZLAFF, MH .
VETERINARY SURGERY, 1988, 17 (03) :117-127