A prospective randomised study comparing rotating platform and fixed bearing total knee arthroplasty in a cruciate substituting design - Outcomes at two year follow-up

被引:34
作者
Ferguson, K. B. [1 ]
Bailey, O. [1 ]
Anthony, I. [1 ]
James, P. J. [2 ]
Stother, I. G. [1 ]
Blyth, M. J. G. [1 ]
机构
[1] Glasgow Royal Infirm, Dept Orthopaed & Trauma, Glasgow, Lanark, Scotland
[2] City Hosp Nottingham, Dept Orthopaed & Trauma, Nottingham, England
关键词
Mobile bearing; Knee arthroplasty; Fixed bearing; Total knee arthroplasty; MOBILE-BEARING; CONTROLLED-TRIAL; CLINICAL-TRIAL; REPLACEMENTS; PROSTHESES; PATIENT; METAANALYSIS; MINIMUM; FLEXION;
D O I
10.1016/j.knee.2013.09.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Fixed bearing (FB) total knee replacement is a well established technique against which new techniques must be compared. Mobile bearing (MB) prostheses, in theory, reduce polyethylene wear but the literature is yet to provide evidence that they are superior in terms of function or long-term survivorship. In addition there has been no comparison of patella resurfacing on the outcome of either design. The aims of this randomised prospective study were firstly to determine whether a mobile bearing prosthesis produced better clinical outcome and range of motion at two year follow-up and secondly to assess the effect of patella resurfacing on the outcomes of both types of bearing design. Methods: Three hundred fifty-two patients were randomised into receiving either a PFC Sigma (c) cruciate sacrificing total knee arthroplasty either with a mobile bearing or a fixed bearing, with a sub-randomisation to either patella resurfacing or patella retention. All patients participated with standard clinical outcome measures and had their range of motion measured both pre-operatively and at follow-up. Results: The mobile bearing TKR design had no impact on range of motion; Oxford Knee Score and American Knee Society knee and function scores when compared to its fixed bearing equivalent. Conclusions: At two year follow-up there was no difference between the PFC Sigma (c) fixed and mobile bearing designs. With no clinical difference between the cohorts, we cannot recommend one design over the other. Long term benefits, particularly with regards to polyethylene wear, may yet be demonstrated. Level of evidence - 1B. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 33 条
[1]
Comparison of mobile-bearing and fixed-bearing total knee arthroplasty - A prospective randomized study [J].
Aglietti, P ;
Baldini, A ;
Buzzi, R ;
Lup, D ;
De Luca, L .
JOURNAL OF ARTHROPLASTY, 2005, 20 (02) :145-153
[2]
The influence of an anterior-posterior gliding mobile bearing on range of motion after total knee arthroplasty - A prospective, randomized, double-blinded study [J].
Aigner, C ;
Windhager, R ;
Pechmann, M ;
Rehak, P ;
Engeleke, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2257-2262
[3]
The Outcome of Rotating-Platform Total Knee Arthroplasty with Cement at a Minimum of Ten Years of Follow-up [J].
Argenson, Jean-Noel A. ;
Parratte, Sebastien ;
Ashour, Abdullah ;
Saintmard, Bertrand ;
Aubaniac, Jean-Manuel .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (07) :638-644
[4]
Fixed Versus Rotating Platform Total Knee Arthroplasty: A Prospective, Randomized, Single-Blind Study [J].
Ball, Scott T. ;
Sanchez, Hugo B. ;
Mahoney, Ormonde M. ;
Schmalzried, Thomas P. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (04) :531-536
[5]
A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years [J].
Bhan, S ;
Malhotra, R ;
Kiran, EK ;
Shukla, S ;
Bijjawara, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (10) :2290-2296
[6]
Primary total knee arthroplasty using the PFC Sigma®-rotating platform cruciate retaining endoprosthesis - A 6 year follow up [J].
Bhatt, H. ;
Rambani, R. ;
White, W. ;
Chakrabarty, G. .
KNEE, 2012, 19 (06) :856-859
[7]
THE POSTERIOR STABILIZED TOTAL KNEE PROSTHESIS - ASSESSMENT OF POLYETHYLENE DAMAGE AND OSTEOLYSIS AFTER A 10-YEAR-MINIMUM FOLLOW-UP [J].
COLIZZA, WA ;
INSALL, JN ;
SCUDERI, GR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) :1713-1720
[8]
Questionnaire on the perceptions of patients about total knee replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :63-69
[9]
Comparative flexion after rotating-platform vs fixed-bearing total knee arthroplasty [J].
Evans, Matthew C. ;
Parsons, Eric M. ;
Scott, Richard D. ;
Thornhill, Thomas S. ;
Zurakowski, David .
JOURNAL OF ARTHROPLASTY, 2006, 21 (07) :985-991
[10]
Rotating Platform Spinouts with Cruciate-Retaining Mobile-Bearing Knees [J].
Fisher, David A. ;
Bernasek, Thomas L. ;
Puri, Rajeev D. ;
Burgess, Mary L. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :877-882