Influence of a Paclitaxel Coated Balloon in Combination With a Bare Metal Stent on Restenosis and Endothelial Function: Comparison With a Drug Eluting Stent and a Bare Metal Stent

被引:22
作者
Clever, Yvonne P. [1 ]
Cremers, Bodo [1 ]
Speck, Ulrich [2 ]
Dietz, Ulrich [3 ]
Boehm, Michael [1 ]
Scheller, Bruno [1 ]
机构
[1] Univ Klinikum Saarlandes, Innere Med Klin 3, Homburg, Germany
[2] Humboldt Univ, Charite, Inst Radiol, D-10099 Berlin, Germany
[3] Deutsch Klin Diagnost, Wiesbaden, Germany
关键词
drug coated balloon; drug eluting stent; endothelial function; VASOMOTOR FUNCTION; FOLLOW-UP; CORONARY; ANGIOPLASTY; DYSFUNCTION; INHIBITION; PREVENTION; STANDARD; CATHETER; STENOSES;
D O I
10.1002/ccd.25184
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Different approaches of local intravascular drug delivery may influence endothelial and microvascular function. The aim of this trial was to study the influence of a paclitaxel coated balloon in combination with a bare metal stent (DCB + BMS) versus a bare metal stent (BMS) or a sirolimus- eluting stent (DES) on coronary restenosis and endothelial function. Methods and Results: This prospective trial included 77 patients with coronary de novo lesions. The patients were assigned to either one of the treatment groups. After 9 months, patients underwent angiographic follow- up including invasive measurement of coronary endothelial function. After 9 months, late lumen loss in- stent was highest in the BMS group (0.85 +/- 0.73 mm), lower in DCB1BMS (0.36 +/- 0.46 mm); and lowest in the DES group (0.25 +/- 0.34 mm; P = 0.001 [ANOVA]). When compared to the BMS group, insegment late lumen loss was significantly reduced in the DCB + BMS group (0.27 +/- 0.43 mm vs. 0.60 +/- 0.55 mm, P = 0.029) and the DES group (0.28 +/- 0.40 mm, P = 0.045). Coronary flow reserve was significantly higher with the DCB + BMS treatment (3.1660.97 vs. 2.42 +/- 0.99 [BMS], P = 0.036) whereas the increase in the DES group did not reach the significance level (3.06 +/- 1.39, P = 0.144 vs. BMS). Parameters of endothelial function like intracoronary flow velocity and vessel diameter distal to the stented area showed similar patterns of response to adenosine, acetylcholine, and nitro in all groups. Conclusion: DES and the combination of DCB1BMS showed a significant reduction of late lumen loss as compared to a BMS alone. Furthermore, both types of local drug delivery were not associated with a deterioration of microvascular function at 9 months [Clinical-Trials. gov Identifier: NCT00473499]. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 45 条
[1]  
Ali RM, 2011, EUROINTERVENTION, V7, pK83, DOI 10.4244/EIJV7SKA15
[2]   Comparison of two drug-eluting balloons: a report from the SCAAR registry [J].
Bondesson, Per ;
Lagerqvist, Bo ;
James, Stefan K. ;
Olivecrona, Goran K. ;
Venetsanos, Dimitrios ;
Harnek, Jan .
EUROINTERVENTION, 2012, 8 (04) :444-449
[3]  
Clever YP, 2011, EUROINTERVENTION, V7, pK32, DOI 10.4244/EIJV7SKA6
[4]   Long-term effects on vascular healing of bare metal stents delivered via paclitaxel-coated balloons in the porcine model of restenosis [J].
Cremers, Bodo ;
Milewski, Krzysztof ;
Clever, Yvonne P. ;
Aboodi, Michael S. ;
Biedermann, Melanie ;
Thim, Troels ;
Kelsch, Bettina ;
Kaluza, Greg L. ;
Scheller, Bruno ;
Granada, Juan F. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (04) :603-610
[5]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[6]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[7]   Paclitaxcel-coated balloon plus bare metal stent vs. sirolimus-eluting stent in de novo lesions: an IVUS study [J].
Fischer, Dieter ;
Scheller, Bruno ;
Schaefer, Arnd ;
Klein, Gunnar ;
Boehm, Michael ;
Clever, Yvonne ;
Cremers, Bodo .
EUROINTERVENTION, 2012, 8 (04) :450-455
[8]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[9]   Impaired endothelial vasomotor function after sirolimus-eluting stent implantation [J].
Fuke, Soichiro ;
Maekawa, Kiyoaki ;
Kawamoto, Kenji ;
Saito, Hironori ;
Sato, Tetsuya ;
Hioka, Toru ;
Ohe, Tohru .
CIRCULATION JOURNAL, 2007, 71 (02) :220-225
[10]   TRANS-LUMINAL DILATATION OF CORONARY-ARTERY STENOSIS [J].
GRUNTZIG, A .
LANCET, 1978, 1 (8058) :263-263