Urea hydrogen peroxide determination in whole blood using europium tetracycline probe

被引:22
作者
Courrol, Lilia C. [1 ]
Bellini, Maria H.
Tarelho, Luiz V. G.
Silva, Flavia R. O.
Mansano, Ronaldo D.
Gomes, Laercio
Vieira, Nilson D., Jr.
Shor, Nestor
机构
[1] FATEC SP, CEETEPS, Sao Paulo, Brazil
[2] IPEN, CNEN SP, Sao Paulo, Brazil
[3] EPUSP, LSI, Sao Paulo, Brazil
[4] Univ Fed Sao Paulo, Nefrol, Sao Paulo, Brazil
关键词
lanthanides; optical sensor; glucose; urea hydrogen peroxide; tetracycline; energy transfer;
D O I
10.1016/j.ab.2006.05.015
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
We introduce the use of a lanthanide complex, tetracycline-europium, for the clinical diagnosis of urea hydrogen peroxide in human whole blood. The values obtained agree with the urea concentration variation verified in 49 patients, including 12 predialysis, 12 peritoneal, and 15 dialysis subjects, and 10 controls. This method is noninvasive and can help in the identification of renal and cardiac diseases. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 19 条
[1]
ROLE OF OXIDATIVE STRESS IN DEVELOPMENT OF COMPLICATIONS IN DIABETES [J].
BAYNES, JW .
DIABETES, 1991, 40 (04) :405-412
[2]
Lifetime- and color-tailored fluorophores in the micro- to millisecond time regime [J].
Chen, JY ;
Selvin, PR .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (04) :657-660
[3]
CRAIG G, 2000, ANAL BIOCHEM, V284, P217
[4]
Enhancement of europium luminescence in tetracycline-europium complexes in the presence of urea hydrogen peroxide [J].
da Silva, FR ;
Courrol, LC ;
Tarelho, LVG ;
Gomes, L ;
Vieira, ND .
JOURNAL OF FLUORESCENCE, 2005, 15 (05) :667-671
[5]
Energy transfer from organics to rare-earth complexes [J].
Díaz-García, MA ;
De Avila, SF ;
Kuzyk, MG .
APPLIED PHYSICS LETTERS, 2002, 81 (21) :3924-3926
[6]
Nonenzymatic direct assay of hydrogen peroxide at neutral pH using the Eu3Tc fluorescent probe [J].
Dürkop, A ;
Wolfbeis, OS .
JOURNAL OF FLUORESCENCE, 2005, 15 (05) :755-761
[7]
LANTHANIDE-SENSITIZED LUMINESCENCE FOR THE DETECTION OF TETRACYCLINES [J].
HIRSCHY, LM ;
DOSE, EV ;
WINEFORDNER, JD .
ANALYTICA CHIMICA ACTA, 1983, 147 (MAR) :311-316
[8]
EFFECTS OF KIDNEY OR KIDNEY-PANCREAS TRANSPLANTATION ON PLASMA PENTOSIDINE [J].
HRICIK, DE ;
SCHULAK, JA ;
SELL, DR ;
FOGARTY, JF ;
MONNIER, VM .
KIDNEY INTERNATIONAL, 1993, 43 (02) :398-403
[9]
SERUM GLYCATED ALBUMIN AND FRUCTOSAMINE IN RENAL DIALYSIS PATIENTS [J].
LAMB, E ;
VENTON, TR ;
CATTELL, WR ;
DAWNAY, A .
NEPHRON, 1993, 64 (01) :82-88
[10]
Identification of pentosidine as a native structure for advanced glycation end products in beta(2)-microglobulin-containing amyloid fibrils in patients with dialysis-related amyloidosis [J].
Miyata, T ;
Taneda, S ;
Kawai, R ;
Ueda, Y ;
Horiuchi, S ;
Hara, M ;
Maeda, K ;
Monnier, VM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (06) :2353-2358