Bone strength and material properties of the glenoid

被引:68
作者
Frich, LH [1 ]
Jensen, NC [1 ]
Odgaard, A [1 ]
Pedersen, CM [1 ]
Sojbjerg, JO [1 ]
Dalstra, M [1 ]
机构
[1] AARHUS UNIV HOSP,SHOULDER & ELBOW CLIN,DK-8200 AARHUS N,DENMARK
关键词
D O I
10.1016/S1058-2746(97)90029-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The qualify of the glenoid bone is important to a successful total shoulder replacement. Finite element models have been used to model the response of the glenoid bone to an implanted prosthesis. Because very little is known about the bone strength and the material properties at the glenoid, these models were all based on assumptions that the material properties of the glenoid were similar to those of the tibial plateau. The osteopenetrometer was used to assess the topographic strength distribution at the glenoid. Strength at the proximal subchondral level of the glenoid averaged 66.9 MPa. Higher peak values were measured posteriorly, superiorly, and anteriorly to the area of maximum concavity of the glenoid joint surface known as the bare area. One millimeter underneath the subchondral plate, average strength decreased by 25%, and at the 2 mm level strength decreased by 70%. The contribution of the cortical bone to the total glenoid strength was assessed by compression tests of pristine and cancellous-free glenoid specimens. Strength decreased by an average of 31% after the cancellous bone was removed. The material properties of the glenoid cancellous bone were determined by axial compression tests of bone specimens harvested from the central part of the glenoid subchondral area. The elastic modulus varied from approximately 100 MPa at the glenoid bare area to 400 MPa at the superior part of the glenoid. With the elastic constants used as a predictor of the mechanical anisotropy, the average anisotropy ratio was 5.2, indicating strong anisotropy. The apparent density was on average 0.35 gr. cm(-3), and the Poisson ratio averaged 0.263. According to our findings the anisotropy of the glenoid cancellous bone, details concerning the strength distribution, and the load-bearing function of the cortical shell should be considered in future finite element models of the glenoid.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 28 条
[1]  
ARMITAGE P, 1987, STATISTICAL METHODS, P104
[2]   MECHANICAL STRENGTH OF TIBIAL TRABECULAR BONE EVALUATED BY X-RAY COMPUTED-TOMOGRAPHY [J].
BENTZEN, SM ;
HVID, I ;
JORGENSEN, J .
JOURNAL OF BIOMECHANICS, 1987, 20 (08) :743-&
[3]   QUANTITATIVE CT FOR DETERMINATION OF BONE-MINERAL DENSITY - A REVIEW [J].
CANN, CE .
RADIOLOGY, 1988, 166 (02) :509-522
[4]   TRABECULAR BONE REMODELING AROUND SMOOTH AND POROUS IMPLANTS IN AN EQUINE PATELLAR MODEL [J].
CHEAL, EJ ;
SNYDER, BD ;
NUNAMAKER, DM ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1987, 20 (11-12) :1121-1134
[5]   TOTAL SHOULDER ARTHROPLASTY WITH THE NEER PROSTHESIS [J].
COFIELD, RH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (06) :899-906
[6]   MECHANICAL AND TEXTURAL PROPERTIES OF PELVIC TRABECULAR BONE [J].
DALSTRA, M ;
HUISKES, R ;
ODGAARD, A ;
VANERNING, L .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :523-535
[7]  
Figgie H E 3rd, 1988, J Arthroplasty, V3, P123, DOI 10.1016/S0883-5403(88)80077-9
[8]  
FRIEDMAN JR, 1992, J SHOULDER ELB SURG, V1, P261
[10]   LIMITATIONS OF THE CONTINUUM ASSUMPTION IN CANCELLOUS BONE [J].
HARRIGAN, TP ;
JASTY, M ;
MANN, RW ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1988, 21 (04) :269-275