Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery

被引:108
作者
LaDisa, JF
Olson, LE
Guler, I
Hettrick, DA
Audi, SH
Kersten, JR
Warltier, DC
Pagel, PS
机构
[1] Med Coll Wisconsin, Zablocki Vet Affirs Med Ctr, Div Cardiovasc Dis, Dept Anesthesiol, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Zablocki Vet Affairs Med Ctr, Div Cardiovasc Dis, Dept Pulm & Crit Care Med, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Zablocki Vet Affairs Med Ctr, Div Cardiovasc Dis, Dept Pharmacol & Toxicol, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Zablocki Vet Affairs Med Ctr, Div Cardiovasc Dis, Dept Med, Milwaukee, WI 53226 USA
[5] Univ Wisconsin, Dept Biomed Engn, Milwaukee, WI 53201 USA
[6] Boston Sci Corp, Maple Grove, MN 55311 USA
关键词
restenosis; neointimal hyperplasia; endovascular prosthesis; coronary artery disease;
D O I
10.1152/japplphysiol.01329.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Restenosis limits the effectiveness of stents, but the mechanisms responsible for this phenomenon remain incompletely described. Stent geometry and expansion during deployment produce alterations in vascular anatomy that may adversely affect wall shear stress (WSS) and correlate with neointimal hyperplasia. These considerations have been neglected in previous computational fluid dynamics models of stent hemodynamics. Thus we tested the hypothesis that deployment diameter and stent strut properties (e.g., number, width, and thickness) influence indexes of WSS predicted with three-dimensional computational fluid dynamics. Simulations were based on canine coronary artery diameter measurements. Stent-to-artery ratios of 1.1 or 1.2:1 were modeled, and computational vessels containing four or eight struts of two widths (0.197 or 0.329 mm) and two thicknesses (0.096 or 0.056 mm) subjected to an inlet velocity of 0.105 m/s were examined. WSS and spatial WSS gradients were calculated and expressed as a percentage of the stent and vessel area. Reducing strut thickness caused regions subjected to low WSS (<5 dyn/cm(2)) to decrease by similar to87%. Increasing the number of struts produced a 2.75-fold increase in exposure to low WSS. Reducing strut width also caused a modest increase in the area of the vessel experiencing low WSS. Use of a 1.2:1 deployment ratio increased exposure to low WSS by 12-fold compared with stents implanted in a 1.1:1 stent-to-vessel ratio. Thinner struts caused a modest reduction in the area of the vessel subjected to elevated WSS gradients, but values were similar for the other simulations. The results suggest that stent designs that reduce strut number and thickness are less likely to subject the vessel to distributions of WSS associated with neointimal hyperplasia.
引用
收藏
页码:424 / 430
页数:7
相关论文
共 50 条
[1]   Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress [J].
Benard, N ;
Coisne, D ;
Donal, E ;
Perrault, R .
JOURNAL OF BIOMECHANICS, 2003, 36 (07) :991-998
[2]   Vascular smooth muscle growth: Autocrine growth mechanisms [J].
Berk, BC .
PHYSIOLOGICAL REVIEWS, 2001, 81 (03) :999-1030
[3]   Experimental and computational flow evaluation of coronary stents [J].
Berry, JL ;
Santamarina, A ;
Moore, JE ;
Roychowdhury, S ;
Routh, WD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :386-398
[4]   Hemodynamics and wall mechanics of a compliance matching stent: In vitro and in vivo analysis [J].
Berry, JL ;
Manoach, E ;
Mekkaoui, C ;
Rolland, PH ;
Moore, JE ;
Rachev, A .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (01) :97-105
[5]   VASCULAR ENDOTHELIUM RESPONDS TO FLUID SHEAR-STRESS GRADIENTS [J].
DEPAOLA, N ;
GIMBRONE, MA ;
DAVIES, PF ;
DEWEY, CF .
ARTERIOSCLEROSIS AND THROMBOSIS, 1992, 12 (11) :1254-1257
[6]   Pathology of acute and chronic coronary stenting in humans [J].
Farb, A ;
Sangiorgi, G ;
Carter, AJ ;
Walley, VM ;
Edwards, WD ;
Schwartz, RS ;
Virmani, R .
CIRCULATION, 1999, 99 (01) :44-52
[7]   Blood flow in abdominal aortic aneurysms: Pulsatile flow hemodynamics [J].
Finol, EA ;
Amon, CH .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05) :474-484
[8]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[9]  
Fox R.W., 1992, Introduction to Fluid Mechanics, Vfourth
[10]   Computational fluid dynamics and stent design [J].
Frank, AO ;
Walsh, PW ;
Moore, JE .
ARTIFICIAL ORGANS, 2002, 26 (07) :614-621