Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery

被引:108
作者
LaDisa, JF
Olson, LE
Guler, I
Hettrick, DA
Audi, SH
Kersten, JR
Warltier, DC
Pagel, PS
机构
[1] Med Coll Wisconsin, Zablocki Vet Affirs Med Ctr, Div Cardiovasc Dis, Dept Anesthesiol, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Zablocki Vet Affairs Med Ctr, Div Cardiovasc Dis, Dept Pulm & Crit Care Med, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Zablocki Vet Affairs Med Ctr, Div Cardiovasc Dis, Dept Pharmacol & Toxicol, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Zablocki Vet Affairs Med Ctr, Div Cardiovasc Dis, Dept Med, Milwaukee, WI 53226 USA
[5] Univ Wisconsin, Dept Biomed Engn, Milwaukee, WI 53201 USA
[6] Boston Sci Corp, Maple Grove, MN 55311 USA
关键词
restenosis; neointimal hyperplasia; endovascular prosthesis; coronary artery disease;
D O I
10.1152/japplphysiol.01329.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Restenosis limits the effectiveness of stents, but the mechanisms responsible for this phenomenon remain incompletely described. Stent geometry and expansion during deployment produce alterations in vascular anatomy that may adversely affect wall shear stress (WSS) and correlate with neointimal hyperplasia. These considerations have been neglected in previous computational fluid dynamics models of stent hemodynamics. Thus we tested the hypothesis that deployment diameter and stent strut properties (e.g., number, width, and thickness) influence indexes of WSS predicted with three-dimensional computational fluid dynamics. Simulations were based on canine coronary artery diameter measurements. Stent-to-artery ratios of 1.1 or 1.2:1 were modeled, and computational vessels containing four or eight struts of two widths (0.197 or 0.329 mm) and two thicknesses (0.096 or 0.056 mm) subjected to an inlet velocity of 0.105 m/s were examined. WSS and spatial WSS gradients were calculated and expressed as a percentage of the stent and vessel area. Reducing strut thickness caused regions subjected to low WSS (<5 dyn/cm(2)) to decrease by similar to87%. Increasing the number of struts produced a 2.75-fold increase in exposure to low WSS. Reducing strut width also caused a modest increase in the area of the vessel experiencing low WSS. Use of a 1.2:1 deployment ratio increased exposure to low WSS by 12-fold compared with stents implanted in a 1.1:1 stent-to-vessel ratio. Thinner struts caused a modest reduction in the area of the vessel subjected to elevated WSS gradients, but values were similar for the other simulations. The results suggest that stent designs that reduce strut number and thickness are less likely to subject the vessel to distributions of WSS associated with neointimal hyperplasia.
引用
收藏
页码:424 / 430
页数:7
相关论文
共 50 条
[21]   PULSATILE FLOW AND ATHEROSCLEROSIS IN THE HUMAN CAROTID BIFURCATION - POSITIVE CORRELATION BETWEEN PLAQUE LOCATION AND LOW AND OSCILLATING SHEAR-STRESS [J].
KU, DN ;
GIDDENS, DP ;
ZARINS, CK ;
GLAGOV, S .
ARTERIOSCLEROSIS, 1985, 5 (03) :293-302
[22]   The effect of proximal artery flow on the hemodynamics at the distal anastomosis of a vascular bypass graft: Computational study [J].
Kute, SH ;
Vorp, DA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (03) :277-283
[23]   Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation [J].
LaDisa, JF ;
Guler, I ;
Olson, LE ;
Hettrick, DA ;
Kersten, JR ;
Warltier, DC ;
Pagel, PS .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (08) :972-980
[24]   Stent implantation alters coronary artery hemodynamics and wall shear stress during maximal vasodilation [J].
LaDisa, JF ;
Hettrick, DA ;
Olson, LE ;
Guler, I ;
Gross, ER ;
Kress, TT ;
Kersten, JR ;
Warltier, DC ;
Pagel, PS .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (06) :1939-1946
[25]   Geometric design improvements for femoral graft-artery junctions mitigating restenosis [J].
Lei, M ;
Kleinstreuer, C ;
Archie, JP .
JOURNAL OF BIOMECHANICS, 1996, 29 (12) :1605-1614
[26]   A focal stress gradient-dependent mass transfer mechanism for atherogenesis in branching arteries [J].
Lei, M ;
Kleinstreuer, C ;
Truskey, GA .
MEDICAL ENGINEERING & PHYSICS, 1996, 18 (04) :326-332
[27]   Pattern formation of vascular smooth muscle cells subject to nonuniform fluid shear stress:: role of PDGF-β receptor and Src [J].
Liu, SQ ;
Tieche, C ;
Tang, DL ;
Alkema, P .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (03) :H1081-H1090
[28]   Pattern formation of vascular smooth muscle cells subject to nonuniform fluid shear stress: mediation by gradient of cell density [J].
Liu, SQ ;
Tang, DL ;
Tieche, C ;
Alkema, PK .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (03) :H1072-H1080
[29]   Control of the shape of a thrombus-neointima-like structure by blood shear stress [J].
Liu, SQ ;
Zhong, L ;
Goldman, J .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (01) :30-36
[30]   Role of blood shear stress in the regulation of vascular smooth muscle cell migration [J].
Liu, SQ ;
Goldman, J .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (04) :474-483