Serum and plasma latex agglutination tests for detection of fibrin(ogen) degradation products in clinically ill dogs

被引:11
作者
Boisvert, AM [1 ]
Swenson, CL
Haines, CJ
机构
[1] Michigan State Univ, Dept Vet Pathol, E Lansing, MI 48824 USA
[2] Michigan State Univ, Vet Teaching Hosp, Clin Pathol Lab, E Lansing, MI 48824 USA
关键词
coagulopathy; DIC; dog; FDP; method comparison; plasma;
D O I
10.1111/j.1939-165X.2001.tb00421.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
An increased concentration of fibrin(ogen) degradation products (FDPs) commonly is used in conjunction with other hemostatic test abnormalities to identify patients with disseminated intravascular coagulation (DIC). Positive FDP results, however, have been observed in dogs without clinical evidence of DIC. The purpose of this study was to evaluate FDP concentrations in a group of clinically ill dogs with a variety of disorders. Dogs included in the study had the following hemostatic parameters evaluated: prothrombin time, activated partial thromboplastin time, fibrinogen concentration, platelet count, and FDP concentration. Two rapid latex agglutination methods were compared for detecting FDP in serum samples (Thrombo-Wellcotest, International Murex Technologies Corp) and plasma samples (FDP Plasma, American Bioproducts Inc). Results of the serum FDP method were positive in 8% (4/50) of the dogs tested: 3 with DIC and 1 with immune-mediated hemolytic anemia and liver disease. Results of the plasma FDP test were positive in 60% (30/50) of the animals tested: 6 with DIC, 3 with confirmed thrombosis, and 21 with a variety of conditions, including neoplasia, immune-mediated hemolytic anemia, pancreatitis, gastric dilatation-volvulus, heat stroke, severe trauma, sepsis, protein-losing nephropathy, liver disease, hyperadrenocorticism, and chronic heart failure. Because the plasma FDP test was positive more frequently than the serum FDP test in ill dogs, it may be more sensitive for the detection of canine FDP, (C) 2001 American Society for Veterinary Clinical Pathology.
引用
收藏
页码:133 / 136
页数:4
相关论文
共 11 条
[1]  
*AM BIOPR INC, 1997, VDP PLASM PACK INS
[2]  
Caldin M., 1998, J VET INTERN MED, V12, P236
[3]   A LATEX IMMUNOASSAY OF FIBRIN FIBRINOGEN DEGRADATION PRODUCTS IN PLASMA USING A MONOCLONAL-ANTIBODY [J].
MIRSHAHI, M ;
SORIA, J ;
SORIA, C ;
PERROT, JY ;
BOUCHEIX, C .
THROMBOSIS RESEARCH, 1986, 44 (06) :715-728
[4]   CHANGES IN PLASMA FIBRIN DEGRADATION PRODUCTS AS A MARKER OF THROMBUS EVOLUTION IN PATIENTS WITH DEEP-VEIN THROMBOSIS [J].
MIRSHAHI, M ;
SORIA, C ;
SORIA, J ;
MIRSHAHI, M ;
FAIVRE, R ;
KIEFFER, Y ;
BASSAND, JP ;
TOULEMONDE, F ;
CAEN, J .
THROMBOSIS RESEARCH, 1988, 51 (03) :295-302
[5]   Anticoagulant rodenticide toxicity in 21 dogs [J].
Sheafor, SE ;
Couto, CG .
JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1999, 35 (01) :38-46
[6]  
Stokol T, 1999, J VET INTERN MED, V13, P478, DOI 10.1892/0891-6640(1999)013&lt
[7]  
0478:EOKFTD&gt
[8]  
2.3.CO
[9]  
2
[10]   PLASMA ALPHA-2-PLASMIN INHIBITOR-PLASMIN COMPLEX AND FDP-D-DIMER IN FULMINANT HEPATIC-FAILURE [J].
TOMIYA, T ;
HAYASHI, S ;
OGATA, I ;
FUJIWARA, K .
THROMBOSIS RESEARCH, 1989, 53 (03) :253-260