Short-Circuit Fault Diagnosis for Three-Phase Inverters Based on Voltage-Space Patterns

被引:77
作者
Alavi, Marjan [1 ,2 ]
Wang, Danwei [3 ]
Luo, Ming [2 ]
机构
[1] Nanyang Technol Univ, Coll Engn, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Singapore Inst Mfg Technol, Singapore 638075, Singapore
[3] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
关键词
Fault detection and isolation (FDI); fault diagnosis; inverter; motor drive; pattern analysis; pulsewidth modulation (PWM); short-circuit fault; state transition; voltage space; SWITCH FAULTS; STRATEGIES; SCHEME; DRIVE;
D O I
10.1109/TIE.2013.2297298
中图分类号
TP [自动化技术、计算机技术];
学科分类号
080201 [机械制造及其自动化];
摘要
This paper introduces a fault detection and isolation (FDI) method for faulty metal-oxide-semiconductor field-effect transistors in a three-phase pulsewidth-modulated (PWM) voltage source inverter. Short-circuit switch faults are the leading cause of failure in power converters. It is extremely vital to detect them in the early stages to prevent unwanted shutdown and catastrophic failures in motor drives and power generation systems. Against the common FDI methods for power electronic inverters that use phase currents and PWM gate control signals, the proposed method only uses the inverter output voltages. This method analyzes the PWM switching signals in a time-free domain that is called the voltage space. For a healthy inverter, the projection of the state transitions in the voltage space results in a cubic pattern. Each short-circuit switch fault uniquely changes the voltage-space pattern that allows isolating the faulty switch. The fault detection time is only within one PWM carrier period, which is significantly faster than current-based conventional methods. The FDI result does not depend on the load, the PWM switching frequency, and the feedback loop. This method can address the reliability problem of multilevel inverters in renewable electrical generation systems and can dramatically reduce the number of required sensors.
引用
收藏
页码:5558 / 5569
页数:12
相关论文
共 34 条
[1]
[Anonymous], 3 PHASE PULSE WIDTH
[2]
[Anonymous], P IET RES
[3]
[Anonymous], P IEEE ICIT
[4]
[Anonymous], 2011, LECT NOTES ELECT ENG
[5]
[Anonymous], P IEEE IECON IECON
[6]
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System [J].
Antonio Rodriguez-Blanco, Marco ;
Claudio-Sanchez, Abraham ;
Theilliol, Didier ;
Gerardo Vela-Valdes, Luis ;
Sibaja-Teran, Pedro ;
Hernandez-Gonzalez, Leobardo ;
Aguayo-Alquicira, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1625-1633
[7]
Bhambra J. K., 2011, 2011 8th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED 2011), P133, DOI 10.1109/DEMPED.2011.6063613
[8]
Harmonic current sideband-based novel indicators of broken bars for on-line evaluation of industrial and railway cage motor faults [J].
Bruzzese, Claudio ;
Honorati, Onorato ;
Santini, Ezio .
2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, :1252-1257
[9]
A New Fault Diagnosis Method and a Fault-Tolerant Switching Strategy for Matrix Converters Operating With Optimum Alesina-Venturini Modulation [J].
Cruz, Sergio M. A. ;
Mendes, Andre M. S. ;
Marques Cardoso, Antonio J. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (01) :269-280
[10]
Pulsewidth Modulation Strategies Nonsinusoidal Carrier-Based PWM and Space Vector Modulation Techniques [J].
da Silva, Edison Roberto C. ;
dos Santos, Euzeli Cipriano, Jr. ;
Jacobina, Cursino Brandao .
IEEE INDUSTRIAL ELECTRONICS MAGAZINE, 2011, 5 (02) :37-45