A novel flow injection ( FI) on-line column preconcentration system, coupled to electrothermal atomic absorption spectrometry (ETAAS) for ultra-trace cobalt determination, has been developed. Polytetra uoroethylene ( PTFE) turnings are used as sorbent material. The sample is mixed on-line with ammonium pyrrolidine dithiocarbamate (APDC) and the non-charged Co-II-PDC complex is retained on the hydrophobic PTFE turnings at a pH range of 5.5-7.0. The preconcentrated complex is effectively eluted with a discrete zone of 35 mul isobutyl methyl ketone (IBMK). Airflow is used to introduce the eluent into the transversely heated graphite tube atomizer, through the column. With 60 s preconcentration time and 11.5 ml min(-1) sample flow rate the enhancement factor is 87 and the sample frequency is 20 h(-1). The detection limit is c(L) = 4 ng l(-1), the relative standard deviation is 4.5% at the 0.1 mug l(-1) level and the calibration curve is linear over the concentration range 0.01-0.25 mug l(-1). The proposed method was evaluated by analyzing certified reference materials of water and mussel tissue. Finally, it was successfully applied to the analysis of natural waters and biological samples.
引用
收藏
页码:1330 / 1334
页数:5
相关论文
共 23 条
[1]   Flame atomic absorption spectrometric determination of chromium(VI) by on-line preconcentration system using a PTFE packed column [J].
Anthemidis, AN ;
Zachariadis, GA ;
Kougoulis, JS ;
Stratis, JA .
TALANTA, 2002, 57 (01) :15-22
[2]   On-line solid phase extraction system using PTFE packed column for the flame atomic absorption spectrometric determination of copper in water samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2001, 54 (05) :935-942
[3]   DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION [J].
AZEREDO, LC ;
STURGEON, RE ;
CURTIUS, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) :91-98
[4]   DESIGN AND EVALUATION OF AN ONLINE MICROCOLUMN PRE-CONCENTRATION TECHNIQUE FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BEINROHR, E ;
CAKRT, M ;
RAPTA, M ;
TARAPCI, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :1005-1007
[5]  
Benkhedda I, 1999, J ANAL ATOM SPECTROM, V14, P957
[6]   Electrothermal atomic absorption spectrometric determination of cobalt in biological samples and natural waters using a flow injection system with on-line preconcentration by ion-pair adsorption in a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (2-3) :288-292
[7]   Ultratrace determination of cobalt in natural waters by electrothermal atomic absorption spectrometry using flow-injection on-line sorption preconcentration in a knotted reactor precoated with 1-phenyl-3-methyl-benzoylpyrazol-5-one [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :429-434
[8]   Determination of ultra-trace amounts of cadmium, cobalt and nickel in sea-water by electrothermal atomic absorption spectrometry with on-line preconcentration [J].
Chang, HJ ;
Sung, YH ;
Huang, SD .
ANALYST, 1999, 124 (11) :1695-1699
[9]   FLOW-INJECTION ONLINE SORBENT EXTRACTION PRECONCENTRATION FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, Z ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :639-646
[10]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION ONLINE SORPTION PRECONCENTRATION [J].
FANG, ZL ;
XU, SK ;
DONG, LP ;
LI, WQ .
TALANTA, 1994, 41 (12) :2165-2172