Colour correspondence of a ceramic system in two different shade guides

被引:27
作者
Corciolani, Gabriele [1 ]
Vichi, Alessandro [1 ]
Goracci, Cecilia [1 ]
Ferrari, Marco [1 ]
机构
[1] Univ Siena, Sch Dent, Dept Dent Mat, I-53100 Siena, Italy
关键词
Colour reliability; Clinical spectrophotometer; PFM crowns; 3D Master shade guide; REPEATABILITY; PORCELAIN; TEETH;
D O I
10.1016/j.jdent.2008.10.001
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Objectives: The aim of this study was to test by means of a clinical spectrophotometer the ability of a ceramic system to correctly reproduce the selected shade with reference to two available shade guides. Methods: One shade for each guide of Vita Omega 900 ceramic system (Vita Zahnfabrik, Germany) was selected: A3 for the system based on Vitapan Classical; 2M3 for the system based on Vitapan 3D Master. Fifteen discs were fabricated for each ceramic using a proprietary steel mould that allowed to control the thickness of each layer. The total thickness of the specimen was 1.6 mm. The thickness of the metal base disc was 0.3 mm, while opaque was layered in OAS mm. Dentin opaque (0.25-0.45 mm), dentin (0.5-0.7 mm), and enamel (0.1-0.3 mm) were then layered following manufacturer's patterns. Each layer thickness was checked after firing. Easyshade (Vita Zahnfabrik, Germany) clinical spectrophotometer was used for colour comparison. "Restoration" mode was selected using A3 and 2M3 shades as comparison. The obtained Delta E values were statistically analyzed with the Two-Way Analysis of Variance and the Tukey Test. Results: A closer colour correspondence resulted for the ceramic based on Vitapan 3D Master (Delta E = 1.80 +/- 0.42) than for Omega 900 in Vitapan Classical (Delta E = 2.94 +/- 0.12) (p<0.001). Conclusions: The shade matching ability of the VITA 3D-Master Tooth Guide was found to be more reliable than that of the VITA Classical Shade Guide for Omega 900. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:98 / 101
页数:4
相关论文
共 17 条
[1]
Baltzer A, 2005, Int J Comput Dent, V8, P129
[2]
Coverage error of three conceptually different shade guide systems to vital unrestored dentition [J].
Bayindir, Funda ;
Kuo, Shanglun ;
Johnston, William M. ;
Wee, Alvin G. .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (03) :175-185
[3]
CLARKE FJJ, 1983, DENT CERAMICS
[4]
Corciolani G., 2006, INT DENT S AFRICA, V8, P62
[5]
Predicting porcelain thickness required for dental shade matches [J].
Douglas, RD ;
Przybylska, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (02) :143-149
[6]
Precision of in vivo colorimetric assessments of teeth [J].
Douglas, RD .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (05) :464-470
[7]
Acceptability of shade differences in metal ceramic crowns [J].
Douglas, RD ;
Brewer, JD .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (03) :254-260
[8]
Intrarater repeatability of shade selections with two shade guides [J].
Hammad, IA .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (01) :50-53
[9]
Reproducibility of tooth color gradation using a computer color-matching technique applied to ceramic restorations [J].
Ishikawa-Nagai, S ;
Ishibashi, K ;
Tsuruta, O ;
Weber, HP .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (02) :129-137
[10]
*JJL TECHN LLC, 2003, VIT EAS TECHN, P5