Two methods for the measurement of voluntary contraction torque in the biceps brachii muscle

被引:11
作者
Farina, D
Merletti, R
Rainoldi, A
Buonocore, M
Casale, R
机构
[1] Politecn Torino, Dipartimento Elettr, Ctr Bioingn, I-10129 Turin, Italy
[2] ASLI Regione Piemonte, Turin, Italy
[3] Inst Sci Interchange Fdn, Turin, Italy
[4] Fdn S Maugeri, Ctr Pavia, Serv Neurofisiopatol, Pavia, Italy
[5] Fdn S Maugeri, Ctr Montescano, Serv Neurofisiopatol, Montescano, Italy
[6] CNR, FiSNeM, Rome, Italy
关键词
MVC measurement; isometric contraction; torque measurement; biceps brachii; electromyography; EMG; fatigue;
D O I
10.1016/S1350-4533(99)00076-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Appropriate measurement of maximal voluntary contraction force of a single limb muscle or of a muscle group is important in clinical and research situations. To measure muscle force, one segment of an isometric measuring brace is fixed to a support and force is applied to the other. The output of this arrangement is affected by additional contributions such as pushing or pulling with the whole body. This paper quantifies the differences between measurements of torque produced by the biceps brachii with the brace fixed versus those produced when the elbow joint was isolated by suspending the brace from cables. No statistically significant differences were found between MVC values observed with the two methods within subjects. However, a statistically significant difference in EMG fatigue indices was observed and attributed to a different sharing of force production among different muscles in the two conditions. We conclude that different brace arrangements may lead to the same maximal force but to different rates of myoelectric manifestations of muscle fatigue since the effort may be shared differently among the muscles of synergic or stabilizing groups. (C) 1999 IPEM, Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:533 / 540
页数:8
相关论文
共 33 条
  • [1] MUSCLES ACROSS THE ELBOW JOINT - A BIOMECHANICAL ANALYSIS
    AN, KN
    HUI, FC
    MORREY, BF
    LINSCHEID, RL
    CHAO, EY
    [J]. JOURNAL OF BIOMECHANICS, 1981, 14 (10) : 659 - +
  • [2] Methods to reduce the variability of EMG power spectrum estimates
    Baratta, RV
    Solomonow, M
    Zhou, BH
    Zhu, M
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) : 279 - 285
  • [3] MOTOR UNIT RECRUITMENT STRATEGY OF KNEE ANTAGONIST MUSCLES IN A STEP-WISE, INCREASING ISOMETRIC CONTRACTION
    BERNARDI, M
    SOLOMONOW, M
    SANCHEZ, JH
    BARATTA, RV
    NGUYEN, G
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 70 (06): : 493 - 501
  • [4] BIEDERMANN H J, 1990, Electromyography and Clinical Neurophysiology, V30, P83
  • [5] A METHOD FOR ASSESSING THE EQUIVALENCE OF REPEATED MEASURES OF MUSCLE FATIGUE RATES ESTIMATED FROM EMG POWER SPECTRUM ANALYSIS
    BIEDERMANN, HJ
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1991, 1 (04) : 288 - 292
  • [6] BOCCARDI S, 1995, CINESOLOGIA
  • [7] MYOELECTRIC SIGNAL CONDUCTION-VELOCITY AND SPECTRAL PARAMETERS - INFLUENCE OF FORCE AND TIME
    BROMAN, H
    BILOTTO, G
    DE LUCA, CJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (05) : 1428 - 1437
  • [8] STRATEGIES FOR MUSCLE ACTIVATION DURING ISOMETRIC TORQUE GENERATION AT THE HUMAN ELBOW
    BUCHANAN, TS
    ROVAI, GP
    RYMER, WZ
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1989, 62 (06) : 1201 - 1212
  • [9] REPRODUCIBILITY OF THE MEAN POWER FREQUENCY OF THE SURFACE ELECTROMYOGRAM
    DAANEN, HAM
    MAZURE, M
    HOLEWIJN, M
    VANDERVELDE, EA
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1990, 61 (3-4) : 274 - 277
  • [10] USE OF THE SURFACE EMG SIGNAL FOR PERFORMANCE EVALUATION OF BACK MUSCLES
    DE LUCA, CJ
    [J]. MUSCLE & NERVE, 1993, 16 (02) : 210 - 216