Band broadening inside the chromatographic column: The interest of a liquid stationary phase

被引:31
作者
Berthod, Alain [1 ]
机构
[1] Univ Lyon, CNRS 5180, Analyt Sci Lab, F-69622 Villeurbanne, France
关键词
theory of chromatography; band broadening; countercurrent chromatography; elution-extrusion; true moving bed; cocurrent chromatography;
D O I
10.1016/j.chroma.2006.05.027
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Band broadening inside chromatographic columns was studied by Giddings 40 years ago. This theory is revisited pointing out that the band width depends only on the band position, x, inside the column and the height equivalent to a theoretical plate, H, and not on the solute affinity for the stationary phase. The band standard deviation, sigma, inside the column is simply sigma = root xH. This property can be used in countercurrent chromatography (CCC), a chromatographic technique that works with a liquid stationary phase. Two possibilities are presented: 1-extrusion of the liquid stationary phase called elution-extrusion method, and 2-slow motion of the stationary phase in the same direction as the mobile phase, called cocurrent CCC method. A mixture of five steroids, prednisone, prednisolone acetate, testosterone, estrone and cholesterol, with partition coefficient varying from 0.1 to 40, is used with a 53 mL CCC column to show the method capabilities. The elution-extrusion method is discontinuous; however, it allows saving dramatic amounts of solvent and time. Cholesterol could be fully resolved in 2 h and 120 mL instead of 7 h and 1.2 L using the classical elution way. The cocurrent CCC method is continuous and was able to resolve cholesterol at baseline in 40 min using 110 mL. Detection is difficult due to the fact that two immiscible liquid phases enter the detector. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:347 / 356
页数:10
相关论文
共 11 条
[1]
Using the liquid nature of the stationary phase in countercurrent chromatography - IV. The cocurrent CCC method [J].
Berthod, A ;
Hassoun, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1116 (1-2) :143-148
[2]
Using the liquid nature of the stationary phase: The elution-extrusion method [J].
Berthod, A ;
Hassoun, M ;
Harris, G .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (12-13) :1851-1866
[3]
Alkane effect in the Arizona liquid systems used in countercurrent chromatography [J].
Berthod, A ;
Hassoun, M ;
Ruiz-Angel, MJ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) :327-340
[4]
BERTHOD A, 1990, ANALUSIS, V18, P352
[5]
Elution-extrusion countercurrent chromatography. Use of the liquid nature of the stationary phase to extend the hydrophobicity window [J].
Berthod, A ;
Ruiz-Angel, MJ ;
Carda-Broch, S .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5886-5894
[6]
Berthod A., 2002, Countercurrent Chromatography: The Support-Free Liquid Stationary Phase
[7]
Conway W. D, 1989, COUNTERCURRENT CHROM
[8]
Giddings J.C., 1965, DYNAMICS CHROMATOG 1, P13
[9]
Giddings J.C, 1991, UNIFIED SEPARATION S, P97
[10]
EFFICIENT PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY WITH A COIL PLANET CENTRIFUGE [J].
ITO, Y .
JOURNAL OF CHROMATOGRAPHY, 1981, 214 (01) :122-125