A low profile human tendon force transducer: The influence of tendon thickness on calibration

被引:13
作者
Dennerlein, JT
Miller, JM
Mote, CD
Rempel, DM
机构
[1] UNIV CALIF SAN FRANCISCO,ERGON PROGRAM,SAN FRANCISCO,CA 94143
[2] SMITH KETTLEWELL EYE RES INST,SAN FRANCISCO,CA 94115
[3] UNIV CALIF BERKELEY,DEPT MECH ENGN,BERKELEY,CA 94720
关键词
tendon; force transducer; finger; force;
D O I
10.1016/S0021-9290(96)00158-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An in vitro calibration method for human tendon force transducers using tendon thickness to predict the calibration factor has been previously proposed (An et al., 1990, J. Biomechanics 23, 1269-1271). However, changes in the calibration factor due to changing tendon geometry during repeated tendon loading are unknown. A new, low-profile transducer design that measures tendon thickness in the transducer, in situ, is developed. An empirical model estimating the transducer's calibration factor is developed using data from in vitro tension testing of 12 fresh frozen human linger flexor tendons. Each tendon is preseated with ten loading cycles before data collection. Using tendon thickness, the model predicts the measured calibration factor to within 0-15% (average 6%). During repeated loading of an in vitro tendon, the calibration factor changes 15% over the first ten cycles (0-50 N) due to the observed changing tendon thickness. After the first ten loading cycles the variability of the calibration factor is reduced to less than 1% for the next three loading cycles. Hence this new, modified in vitro calibration procedure with tendon preseating reduces the cycle-to-cycle variability caused by the associated change in the tendon thickness. (C) 1997 Published by Elsevier Science Ltd.
引用
收藏
页码:395 / 397
页数:3
相关论文
共 14 条
[1]   DIRECT INVIVO TENDON FORCE MEASUREMENT SYSTEM [J].
AN, KN ;
BERGLUND, L ;
COONEY, WP ;
CHAO, EYS ;
KOVACEVIC, N .
JOURNAL OF BIOMECHANICS, 1990, 23 (12) :1269-1271
[2]   IN-VIVO TENDON TENSION AND BONE STRAIN MEASUREMENT AND CORRELATION [J].
BARNES, GRG ;
PINDER, DN .
JOURNAL OF BIOMECHANICS, 1974, 7 (01) :35-42
[3]   MECHANICAL OUTPUT OF THE CAT SOLEUS DURING TREADMILL LOCOMOTION - INVIVO VS INSITU CHARACTERISTICS [J].
GREGOR, RJ ;
ROY, RR ;
WHITING, WC ;
LOVELY, RG ;
HODGSON, JA ;
EDGERTON, VR .
JOURNAL OF BIOMECHANICS, 1988, 21 (09) :721-732
[4]  
KOMI PV, 1987, INT J SPORTS MED, V8, P3
[5]   RELEVANCE OF INVIVO FORCE MEASUREMENTS TO HUMAN BIOMECHANICS [J].
KOMI, PV .
JOURNAL OF BIOMECHANICS, 1990, 23 :23-34
[6]  
Ljung L., 1987, System Identification: Theory for the User
[7]   EXTRAOCULAR-MUSCLE FORCES IN ALERT MONKEY [J].
MILLER, JM ;
ROBINS, D .
VISION RESEARCH, 1992, 32 (06) :1099-1113
[8]  
PERES G, 1983, BIOMECHANICS A, V8, P455
[9]   A METHOD OF MEASURING FINGERTIP LOADING DURING KEYBOARD USE [J].
REMPEL, D ;
DENNERLEIN, J ;
MOTE, CD ;
ARMSTRONG, T .
JOURNAL OF BIOMECHANICS, 1994, 27 (08) :1101-1104
[10]   FLEXOR TENDON FORCES - INVIVO MEASUREMENTS [J].
SCHUIND, F ;
GARCIAELIAS, M ;
COONEY, WP ;
AN, KN .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (02) :291-298