The Tempofilter((R)): A multicenter study of a new temporary caval filter implantable for up to six weeks

被引:58
作者
Bovyn, G
Gory, P
Reynaud, P
Ricco, JB
机构
[1] HOP LAENNEC, SERV REANIMAT PNEUMOL, F-75340 PARIS, FRANCE
[2] CTR HOSP, SERV CHIRURG VASC, ST BRIEUC, FRANCE
[3] CTR HOSPITALOUNIV, SERV CHIRURG VASC, POITIERS, FRANCE
[4] GRP ETUD TEMPOFILTER, ST BRIEUC, FRANCE
关键词
D O I
10.1007/s100169900084
中图分类号
R61 [外科手术学];
学科分类号
摘要
A multicenter study was conducted to evaluate a new temporary caval filler (Tempofilter(R)) designed to be implanted for up to 6 weeks. A total of 66 patients with a mean age of 51.8 years were enrolled in the study. All had documented high risk of pulmonary embolism: severe deep venous thrombosis in 89.5% of cases and previous symptomatic pulmonary embolism in 65% of cases. Filter placement was performed in association with a surgical or obstetrical procedure in 68.5% of cases. The indication for filter placement was contraindication to or-failure of anticoagulant therapy in 85% of the cases. The mean duration of implantation was 29.9 days. Pulmonary embolism was not observed during the implantation period. Partial thrombosis of the filter was observed in 15% of cases due to trapping of clots by the fitter. Thrombosis did not hinder filter removal when attempted. Filter-related complications were minor. Filter migration occurred in only 7.5% of cases. Migration never led to complications and did not hinder filter removal. In all cases migration was due to specific, preventable causes. The results of this study show that the Tempofilter(R) is not only safe and easy to use but also effective in preventing pulmonary embolism. A significantly longer maximum implantation time is a major advantage of the Tempofilter(R) over conventional temporary filters. We believe that this filter can be used far temporary protection against the risk of pulmonary embolism particularly in young patients and in a surgical setting.
引用
收藏
页码:520 / 528
页数:9
相关论文
共 13 条
  • [1] INFERIOR VENA-CAVA FILTERS - INDICATIONS, SAFETY, EFFECTIVENESS
    BECKER, DM
    PHILBRICK, JT
    SELBY, JB
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1992, 152 (10) : 1985 - 1994
  • [2] BOULET E, 1994, SANG THROMBOSE VAISS, V6, P399
  • [3] BOVYN G, 1992, MALADIE THROMBOEMBOL, P211
  • [4] CHEVROLET JC, 1992, REAN SOINS INTENS ME, V7, P19
  • [6] GIRARD P, 1992, SANG THROMBOSE VAISS, V4, P441
  • [7] GREENFIELD LJ, 1991, J VASC SURG, V14, P253
  • [8] COMPLICATIONS FOLLOWING CAVAL INTERRUPTION
    KNIEMEYER, HW
    SANDMANN, W
    BACH, D
    TORSELLO, G
    JUNGBLUT, RM
    GRABENSEE, B
    [J]. EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (05): : 617 - 621
  • [9] MEYER G, 1991, PRESSE MED, V19, P1347
  • [10] COMPARATIVE EFFICACY AND COMPLICATIONS OF VENA-CAVAL FILTERS
    MOHAN, CR
    HOBALLAH, JJ
    SHARP, WJ
    KRESOWIK, TF
    LU, CT
    CORSON, JD
    [J]. JOURNAL OF VASCULAR SURGERY, 1995, 21 (02) : 235 - 246