Elliptically bent slotted waveguide conformal focused array for hyperthermia treatment of tumors in curved region of human body

被引:18
作者
Gupta, R. C. [1 ]
Singh, S. P. [1 ]
机构
[1] Banaras Hindu Univ, Inst Technol, Dept Elect Engn, Varanasi 221005, Uttar Pradesh, India
来源
PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER | 2006年 / 62卷
关键词
D O I
10.2528/PIER06012801
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In present paper, a novel and effective hyperthermia applicator utilizing an elliptically bent conformal array of longitudinal slots in narrow wall of rectangular waveguide is analyzed by two different approaches, viz., the vector potential method and Fresnel-Kirchho. scalar diffraction field theory. The agreement between two theories is reasonably very good. This configuration is mainly intended as a specialized and very effective applicator for hyperthermia treatment of tumor within curved portions of human body such as abdomen, neck, chest etc. Each slot of the conformal array is excited by a coaxial line probe. It is proposed that the interior of the waveguide be filled with water to provide a good impedance match with the bio-medium. The contour distribution of specific absorption rate ( SAR) in x-z plane, SAR distribution in y-direction and parameters such as penetration depth, power absorption coefficient, effective field size (EFS) due to the conformal array as well as single slot are evaluated and compared at 433 MHz. The results for contour SAR distribution at 433MHz for elliptically bent conformal array are also compared with those for other array configurations such as circularly bent conformal array and planar array. The effect of change in phase and amplitude excitation of each slot of the array on SAR distribution is also examined. The results demonstrate that slotted waveguide conformal array offers marked improvement in SAR distribution and penetration depth over single slot. It also has better focusing ability as compared with planar array for controlled amplitude and phase excitations of the elements.
引用
收藏
页码:107 / 125
页数:19
相关论文
共 17 条
[1]  
Castrillo VU, 2003, ICECOM 2003, CONFERENCE PROCEEDINGS, P49
[2]   OPTIMIZATION OF SAR DISTRIBUTIONS IN LIVER AND LUNG REGIONS IRRADIATED BY THE H-HORN ANNULAR PHASED-ARRAY HYPERTHERMIA SYSTEM [J].
DENG, TQ .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1991, 39 (05) :852-856
[3]   FOCUSED ARRAY HYPERTHERMIA APPLICATOR - THEORY AND EXPERIMENT [J].
GEE, W ;
LEE, SW ;
BONG, NK ;
CAIN, CA ;
MITTRA, R ;
MAGIN, RL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (01) :38-46
[4]   ABSORBED POWER DISTRIBUTIONS FROM COHERENT MICROWAVE ARRAYS FOR LOCALIZED HYPERTHERMIA [J].
HAND, JW ;
CHEETHAM, JL ;
HIND, AJ .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :484-489
[5]  
*INT TEL TEL CO, 1968, REF DAT RAD ENG
[6]   DISCUSSION OF CAPABILITIES OF MICROWAVE PHASED-ARRAYS FOR HYPERTHERMIA TREATMENT OF NECK TUMORS [J].
JOUVIE, F ;
BOLOMEY, JC ;
GABORIAUD, G .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :495-501
[7]   A SPHERICAL SLOT ARRAY APPLICATOR FOR MEDICAL APPLICATIONS [J].
KRAIRIKSH, M ;
WAKABAYASHI, T ;
KIRANON, W .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1995, 43 (01) :78-86
[8]   EXPERIMENTAL INVESTIGATION OF A RETRO-FOCUSING MICROWAVE HYPERTHERMIA APPLICATOR - CONJUGATE-FIELD MATCHING SCHEME [J].
LOANE, J ;
LING, H ;
WANG, BF ;
LEE, SW .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :490-494
[9]  
MANSON PA, 2000, IEEE T MICROW THEORY, V48, P2050
[10]   EQUIVALENT-CIRCUIT OF A NARROW-WALL WAVEGUIDE SLOT COUPLER [J].
PANDHARIPANDE, VM ;
DAS, BN .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1979, 27 (09) :800-804