A practical guide to immunoassay method validation

被引:373
作者
Andreasson, Ulf [1 ]
Perret-Liaudet, Armand [2 ]
van Doorn, Linda J. C. van Waalwijk [3 ,4 ]
Blennow, Kaj [1 ]
Chiasserini, Davide [5 ]
Engelborghs, Sebastiaan [6 ,7 ]
Fladby, Tormod [8 ,9 ]
Genc, Sermin [10 ]
Kruse, Niels [11 ]
Kuipenj, H. Bea [3 ,4 ]
Kulic, Luka [12 ]
Lewczuk, Piotr [13 ]
Mollenhauer, Brit [14 ,15 ]
Mroczko, Barbara [16 ]
Pametti, Lucille [5 ]
Vanmechelen, Eugeen [17 ]
Verbeek, Marcel M. [3 ,4 ]
Winblad, Bengt [18 ]
Zetterberg, Henrik [1 ,19 ]
Koel-Simmelink, Marleen [20 ,21 ]
Teunissen, Charlotte E. [20 ,21 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Neurosci & Physiol, Clin Neurochem Lab, S-43180 Molndal, Sweden
[2] Univ Lyon 1, Ctr Memory Resources & Res, Hop Lyon, GHE,Neurobiol Lab,CNRS,UMR5292,INSERM,U1028, F-69365 Lyon, France
[3] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Dept Neurol, Nijmegen, Netherlands
[4] Radboud Alzheimer Ctr, Donders Inst Brain Cognit & Behav, Dept Lab Med, Nijmegen, Netherlands
[5] Univ Perugia, Dept Med, Lab Clin Neurochem, Neurol Sect, I-06100 Perugia, Italy
[6] Univ Antwerp, Inst Born Bunge, Reference Ctr Biol Markers Dementia BIODEM, B-2020 Antwerp, Belgium
[7] Hosp Network Antwerp ZNA Middelheim & Hoge Beuken, Dept Neurol & Memory Clin, Antwerp, Belgium
[8] Univ Oslo, Oslo, Norway
[9] Akershus Univ Hosp, Dept Neurol, Lorenskog, Norway
[10] Dokuz Eylul Univ, Inst Hlth Sci, Dept Neurosci, Izmir, Turkey
[11] Univ Med Ctr, Dept Neuropathol, Gottingen, Germany
[12] Univ Zurich, Div Psychiat Res, Schlieren, Switzerland
[13] Univ Erlangen Nurnberg, Univ Klinikum Erlangen, Dept Psychiat & Psychotherapy, D-91054 Erlangen, Germany
[14] Paracelsus Elena Klin, Kassel, Germany
[15] Univ Med Ctr Gottingen, Dept Neuropathol, Gottingen, Germany
[16] Med Univ Bialystok, Dept Neurodegenerat Diagnost, Bialystok, Poland
[17] ADx NeuroSci, Ghent, Belgium
[18] Karolinska Inst, Stockholm, Sweden
[19] UCL, Inst Neurol, London, England
[20] Vrije Univ Amsterdam, Med Ctr, Neurochem Lab, Amsterdam, Netherlands
[21] Vrije Univ Amsterdam, Med Ctr, Dept Clin Chem, Biobank, Amsterdam, Netherlands
来源
FRONTIERS IN NEUROLOGY | 2015年 / 6卷
基金
瑞典研究理事会;
关键词
immunoassays; method validation; precision; limits of quantitation; robustness; BIOMARKERS;
D O I
10.3389/fneur.2015.00179
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Biochemical markers have a central position in the diagnosis and management of patients in clinical medicine, and also in clinical research and drug development, also for brain disorders, such as Alzheimer's disease. The enzyme-linked immunosorbent assay (ELISA) is frequently used for measurement of low-abundance biomarkers. However, the quality of ELISA methods varies, which may introduce both systematic and random errors. This urges the need for more rigorous control of assay performance, regardless of its use in a research setting, in clinical routine, or drug development. The aim of a method validation is to present objective evidence that a method fulfills the requirements for its intended use. Although much has been published on which parameters to investigate in a method validation, less is available on a detailed level on how to perform the corresponding experiments. To remedy this, standard operating procedures (SOPs) with step-by-step instructions for a number of different validation parameters is included in the present work together with a validation report template, which allow for a well-ordered presentation of the results. Even though the SOPs were developed with the intended use for immunochemical methods and to be used for multicenter evaluations, most of them are generic and can be used for other technologies as well.
引用
收藏
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2017, ISOIEC 170252017
[2]  
[Anonymous], METODVALIDERING HDB
[3]  
[Anonymous], 2001, FED REG
[4]  
[Anonymous], EP06A CLSI
[5]  
[Anonymous], 1994, Accuracy trueness and precision of measurement methods and results
[6]  
[Anonymous], 2004, EVALUATION-US
[7]  
[Anonymous], 151892003 ISO
[8]  
[Anonymous], 1994, ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
[9]   Cerebrospinal fluid and plasma biomarkers in Alzheimer disease [J].
Blennow, Kaj ;
Hampel, Harald ;
Weiner, Michael ;
Zetterberg, Henrik .
NATURE REVIEWS NEUROLOGY, 2010, 6 (03) :131-144
[10]   Recommendations for the bioanalytical method validation of ligand-binding assays to support pharmacokinetic assessments of macromolecules [J].
DeSilva, B ;
Smith, W ;
Weiner, R ;
Kelley, M ;
Smolec, JM ;
Lee, B ;
Khan, M ;
Tacey, R ;
Hill, H ;
Celniker, A .
PHARMACEUTICAL RESEARCH, 2003, 20 (11) :1885-1900