Dosimetry of rhenium-188 diethylene triamine penta-acetic acid for endovascular intra-balloon brachytherapy after coronary angioplasty

被引:29
作者
Lee, J
Lee, DS
Kim, KM
Yeo, JS
Cheon, GJ
Kim, SK
Ahn, JY
Jeong, JM
Chung, JK
Lee, MC
机构
[1] Seoul Natl Univ Hosp, Dept Nucl Med, Chongno Gu, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
关键词
rhenium-188 diethylene triamine penta-acetic acid; dosimetry; MIRD; endovascular brachytherapy; prevention of restenosis;
D O I
10.1007/PL00006667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To examine the possibility of using rhenium-188 diethylene triamine penta-acetic acid (DTPA) for endovascular intra-balloon brachytherapy after angioplasty, dose distribution around the balloon was calculated and validated by film dosimetry. Medical internal radiation dosimetry (MIRD) was calculated assuming that the balloon had ruptured and that the contents had been released into the systemic circulation. Re-188-perrhenate eluate from the W-188/Re-188 generator was concentrated using an ion column and used to label DTPA. The dose distibution around the angioplasty balloon (20 mm length, 3 mm diameter cylinder) was estimated by Monte Carlo simulation using the EGS4 code. The time required for 17.6 Gy to be absorbed at 1 mm from the balloon's surface following application of 3700 MBq/ml Of Re-188 was found to be 278 s. Fifty percent of the energy was deposited in the first millimetre of the vessel wall from the balloon's surface. The calculated radiation absorbed dose agreed with that measured by film dosimetry, which was performed using a water phantom, with errors ranging from 9.4% to 17%. Upon balloon rupture the total amount of Re-188-DTPA was presumed to enter the systemic circulation. The resulting radiation absorbed dose was calculated using the MIRDOSE3 program and residence times obtained from dogs and amounted to 0.0056 mGy/MBq to the whole body and 4.56 mGy/MBq to the urinary bladder. The absorbed dose of 188Re-DTPA to the whole body was one-tenth of that of Re-188-perrhenate. A window-based program was developed to calculate the exposure time and the radiation dose absorbed as a function of the Re-188 concentration and the arbitrary distance from the balloon to the surrounding tissues. We conclude that Re-188-DTPA is easy to prepare, safe to use and suitable for intra-balloon brachytherapy after coronary angioplasty.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 27 条
[1]  
Berger M. J., 1971, Journal of Nuclear Medicine, V12, P5
[2]   Effects of endovascular radiation from a beta-particle-emitting stent in a porcine coronary restenosis model - A dose-response study [J].
Carter, AJ ;
Laird, JR ;
Bailey, LR ;
Hoopes, TG ;
Farb, A ;
Fischell, DR ;
Fischell, RE ;
Fischel, TA ;
Virmani, R .
CIRCULATION, 1996, 94 (10) :2364-2368
[3]  
CHOI YJ, 1998, KOREAN CIRC J, V28, P307
[4]  
Condado JA, 1997, CIRCULATION, V96, P727
[5]  
Crilly RJ, 1997, CIRCULATION, V96, P82
[6]  
Giedd KN, 1997, CIRCULATION, V96, P1215
[7]  
GUHLKE S, 1997, J NUCL MED, V38, P125
[8]  
Joh CW, 1998, J NUCL MED, V39, p85P
[9]   Effect of transcatheter endovascular holmium-166 irradiation on neointimal formation after balloon injury in porcine coronary artery [J].
Kim, HS ;
Cho, YH ;
Kim, JS ;
Oh, YT ;
Kang, HJ ;
Chun, MS ;
Joh, CW ;
Park, CH ;
Tahk, SJ ;
Choi, BW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :277A-277A
[10]   The development of interventional cardiology [J].
King, SB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (04) :64B-88B