Optimal heating-system retrofits in residential buildings

被引:20
作者
Gustafsson, SI [1 ]
Bojic, M [1 ]
机构
[1] UNIV KRAGUJEVAC,FAC MECH ENGN,YU-34000 KRAGUJEVAC,YUGOSLAVIA
关键词
D O I
10.1016/S0360-5442(97)00023-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
The optimal heating-system-retrofit strategy for existing buildings differs due to varying prices of energy, building and installation features, climate conditions, etc. We have examined a test building situated in Linkoping, Sweden. By using the OPERA model, we were able to arrive at the optimal retrofit strategy, which includes a ground-coupled heat pump using electricity to run the compressor. Unfortunately, the price of electricity differs according to the time of day, month, etc. These variations are not included in the OPERA model. In OPERA, the price should be divided into 12 segments, one for each month of the year since climate data are divided in this manner. Fine tuning of a dual-fuel system (an oil-fired boiler handles the peak load and a heat pump the base thermal load) is optimized using the Mixed Integer Linear Programming (MILP) method. Adding a hot-water accumulator also makes it possible to use low electricity prices for space and domestic hot-water heating. This system competes in the model with traditional heating devices such as district heating. The optimal method of heating the building was found for using the heat pump alone. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:867 / 874
页数:8
相关论文
共 9 条
  • [1] FOULDS LR, 1981, OPTIMIZATION TECHNIQ
  • [2] HEAT ACCUMULATORS IN CHP NETWORKS
    GUSTAFSSON, SI
    KARLSSON, BG
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (12) : 1051 - 1061
  • [3] OPTIMIZATION OF BUILDING RETROFITS IN A COMBINED HEAT AND POWER NETWORK
    GUSTAFSSON, SI
    [J]. ENERGY, 1992, 17 (02) : 161 - 171
  • [4] DOES POSTPONED RETROFITTING SAVE MONEY
    GUSTAFSSON, SI
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (05): : 469 - 472
  • [5] GUSTAFSSON SI, 1990, D211990 SWED COUNC B
  • [6] AN OPTIMAL OPERATIONAL ADVISORY SYSTEM FOR A BREWERYS ENERGY SUPPLY PLANT
    ITO, K
    SHIBA, T
    YOKOYAMA, R
    SAKASHITA, S
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1994, 116 (01): : 65 - 71
  • [7] OPTIMAL SCHEDULING OF CYCLIC BATCH PROCESSES FOR HEAT INTEGRATION .1. BASIC FORMULATION
    LEE, B
    REKLAITIS, GV
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 1995, 19 (08) : 883 - 905
  • [8] MARSTEN R, 1985, ZOOM ZERO ONE OPTIMI
  • [9] MIND OPTIMIZATION REDUCES THE SYSTEM COST AT A REFINERY
    NILSSON, K
    SODERSTROM, M
    KARLSSON, BG
    [J]. ENERGY, 1994, 19 (01) : 45 - 54