Feasibility of fitting contact lenses with apical clearance in keratoconus

被引:9
作者
Gundel, RE
Libassi, DP
Zadnik, K
Barr, JT
Davis, L
McMahon, TT
Edrington, TB
Gordon, MO
机构
[1] SUNY State College of Optometry, New York, NY
[2] Ohio State University, College of Optometry, Columbus, OH
[3] University of Missouri-St. Louis, School of Optometry, St. Louis, MO
[4] Department of Ophthalmology, University of Illinois-Chicago, Chicago, IL
[5] Southern California College of Optometry, Fullerton, CA
[6] Department of Ophthalmology and Visual Sciences, Division of Biostatistics, Washington University Medical School, St. Louis, MO
[7] SUNY State College of Optometry, New York, NY 10010
关键词
contact lens fitting; keratoconus; RGP contact lens;
D O I
10.1097/00006324-199612000-00002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Despite the wide variety of rigid contact lens fitting philosophies for the visual correction of keratoconus, questions remain, including which approach-flat, divided support, or steep-contributes the most toward the preservation of a clear cornea, One goal of the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Pilot Study was to determine the feasibility of managing early keratoconus patients with apical clearance rigid contact lenses, Of 30 keratoconus patients identified with at least 1 nonscarred cornea, 17 patients (30 eyes) were randomly assigned to a steep lens fitting protocol, After trial fitting with a standardized lens design demonstrating minimum apical clearance, lenses were dispensed whose base curve was 0.2 mm steeper than the minimum apical clearance lens, Patients were re-evaluated on a quarterly schedule concluding at 12 months, Changes in keratometry between baseline and 12 months identified unequal steepening of the flat and steep corneal curvatures, suggestive of corneal molding, Best corrected rigid lens visual acuity measures illustrated no significant changes over the course of the study. Clinically significant corneal compromise was transiently observed in some patients, Only 1 of 22 eyes completing the pilot study and fitted with apical clearance developed mild corneal scarring.
引用
收藏
页码:729 / 732
页数:4
相关论文
共 8 条
[1]  
BELIN MW, 1988, OPHTHALMOLOGY, V95, P335
[2]   Standardized rigid contact lens fitting protocol for keratoconus [J].
Edrington, TB ;
Barr, JT ;
Zadnik, K ;
Davis, LJ ;
Gundel, RE ;
Libassi, DP ;
McMahon, TT ;
Gordon, MO .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (06) :369-375
[3]  
HALES RH, 1978, CONTACT LENSES CLIN, P114
[4]  
KORB DR, 1982, J AM OPTOM ASSOC, V53, P199
[5]   KERATOCONUS AND RELATED NONINFLAMMATORY CORNEAL THINNING DISORDERS [J].
KRACHMER, JH ;
FEDER, RS ;
BELIN, MW .
SURVEY OF OPHTHALMOLOGY, 1984, 28 (04) :293-322
[6]  
MANDELL RB, 1974, CONTACT LENS PRACTIC, P692
[7]  
TUFT SJ, 1994, OPHTHALMOLOGY, V101, P439
[8]   Biomicroscopic signs and disease severity in keratoconus [J].
Zadnik, K ;
Barr, JT ;
Gordon, MO ;
Edrington, TB .
CORNEA, 1996, 15 (02) :139-146