Storage tank management to improve drinking water quality:: Case study

被引:20
作者
Gauthier, V
Besner, MC
Barbeau, B
Millette, R
Prévost, M
机构
[1] Ecole Polytech, Dept Civ Geol & Min Engn, Chair Drinking Water, NSERC Ind, Montreal, PQ H3C 3A7, Canada
[2] City Montreal Atwater Treatment Plant, Verdun, PQ, Canada
来源
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE | 2000年 / 126卷 / 04期
关键词
D O I
10.1061/(ASCE)0733-9496(2000)126:4(221)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The very marked chlorine decay measured in one section of the distribution system of a large North American city and the fluctuations in this decay were studied. The results obtained from operational data collection, flow measurements, and EPANET hydraulic modeling demonstrate that low chlorine residuals in this particular distribution system section cannot be attributed to any exceptional consumption by corrosion particles, loose deposits, or biofilms. On the contrary, the hydraulic configuration of this distribution system area (tank design and pumping cycles) results in such high residence times in one tank (5.6-7.9 days) that the low chlorine residuals observed are self-explanatory. Detailed analysis of the results indicates that the principles of hydraulic (dys)function in this zone are well described by the model, which can be relied upon to compute and compare several design or operational solutions to minimize residence times. Two of these solutions were field tested and were found to be equally efficient in diminishing the age of water. As a consequence, detectable chlorine residuals were restored in the area.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 35 条
[1]   Seasonal evolution of microbial community structure in a drinking water reservoir [J].
Amblard, C ;
Bourdier, G ;
Carrias, JF ;
Maurin, N ;
Quiblier, C .
WATER RESEARCH, 1996, 30 (03) :613-624
[2]   A MODEL FOR CHLORINE CONCENTRATION DECAY IN PIPES [J].
BISWAS, P ;
LU, CS ;
CLARK, RM .
WATER RESEARCH, 1993, 27 (12) :1715-1724
[3]   Optimal scheduling of booster disinfection in water distribution systems [J].
Boccelli, DL ;
Tryby, ME ;
Uber, JG ;
Rossman, LA ;
Zierolf, ML ;
Polycarpou, MM .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1998, 124 (02) :99-111
[4]  
Boulos PF, 1996, J AM WATER WORKS ASS, V88, P48
[5]   Sampling design methods for water distribution model calibration [J].
Bush, CA ;
Uber, JG .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1998, 124 (06) :334-344
[6]   Mixing in distribution system storage tanks: Its effect on water quality [J].
Clark, RM ;
Abdesaken, F ;
Boulos, PF ;
Mau, RE .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1996, 122 (09) :814-821
[7]   Dynamic modelling of bacterial growth in drinking water networks [J].
Dukan, S ;
Levi, Y ;
Piriou, P ;
Guyon, F ;
Villon, P .
WATER RESEARCH, 1996, 30 (09) :1991-2002
[8]  
ELTON A, 1995, J AM WATER WORKS ASS, V87, P44
[9]   Free chlorine consumption induced by cast iron corrosion in drinking water distribution systems [J].
Frateur, I ;
Deslouis, C ;
Kiene, L ;
Levi, Y ;
Tribollet, B .
WATER RESEARCH, 1999, 33 (08) :1781-1790
[10]   Organic matter as loose deposits in a drinking water distribution system [J].
Gauthier, V ;
Gérard, B ;
Portal, JM ;
Block, JC ;
Gatel, D .
WATER RESEARCH, 1999, 33 (04) :1014-1026