High power light emitting diode (LED) arrays versus halogen light polymerization of oral biomaterials: Barcol hardness, compressive strength and radiometric properties

被引:86
作者
Mills, RW
Uhl, A
Blackwell, GB
Jandt, KD
机构
[1] Univ Bristol, Dept Oral & Dent Sci, Biomed Engn & Biomat Sci Sect, Bristol BS1 2LY, Avon, England
[2] Dentsply DeTrey GmbH, D-78467 Constance, Germany
[3] Univ Jena, Dept Mat Sci & Engn, Tech Inst, D-07743 Jena, Germany
关键词
LED; light curing unit (LCU); composites; polymerization; depth of cure; irradiance; spectrum; mechanical properties; Barcol hardness; compressive strength;
D O I
10.1016/S0142-9612(02)00024-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The clinical performance of light polymerized dental composites is greatly influenced by the quality of the light curing unit (LCU) used. Commonly used halogen LCUs have some specific drawbacks such as decreasing light output with time. This may result in a low degree of monomer conversion of the composites with negative clinical implications. Previous studies have shown that blue light emitting diode (LED) LCUs have the potential to polymerize dental composites without having the drawbacks of halogen LCUs. Since these studies were carried out LED technology has advanced significantly and commercial LED LCUs are now becoming available. This study investigates the Barcol hardness as a function of depth, and the compressive strength of dental composites that had been polymerized for 40 or 20s with two high power LED LCU prototypes, a commercial LED LCU, and a commercial halogen LCU. In addition the radiometric properties of the LCUs were characterized. The two high power prototype LED LCUs and the halo-en LCU showed a satisfactory and similar hardness-depth performance whereas the hardness of the materials polymerized with the commercial LED LCU rapidly decreased with sample depth and reduced polymerization time (20 s). There were statistically significant differences in the overall compressive strengths of composites polymerized with different LCUs at the 95% significance level (p = 0.0016) with the two high power LED LCU prototypes and the halogen LCU forming a statistically homogenous group. In conclusion, LED LCU polymerization technology can reach the performance level of halogen LCUs. One of the first commercial LED LCUs however lacked the power reserves of the high power LED LCU prototypes. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2955 / 2963
页数:9
相关论文
共 29 条
[1]
*AK DENT, 2000, LUX O MAX
[2]
EVALUATING INTENSITY OUTPUT OF CURING LIGHTS IN PRIVATE DENTAL OFFICES [J].
BARGHI, N ;
BERRY, T ;
HATTON, C .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (07) :992-996
[3]
CAUGHMAN WF, 1995, J AM DENT ASSOC, V126, P1280
[4]
*DIN DTSCH I NORM, 1997, DIN TASCH, P267
[5]
DEGREE OF DOUBLE-BOND CONVERSION IN LIGHT-CURED COMPOSITES [J].
ELIADES, GC ;
VOUGIOUKLAKIS, GJ ;
CAPUTO, AA .
DENTAL MATERIALS, 1987, 3 (01) :19-25
[6]
Ferry D, 1998, ARION, V5, P1
[7]
FUJIBAYASHI K, 1998, DENT JPN, V34, P49
[8]
HAITZ RH, 1995, HDB OPTICS
[9]
DETERMINATION OF RADIATION ENERGY EMITTED BY LIGHT ACTIVATION UNITS [J].
HARRINGTON, E ;
WILSON, HJ .
JOURNAL OF ORAL REHABILITATION, 1995, 22 (05) :377-385
[10]
Depth of cure and compressive strength of dental composites cured with blue light emitting diodes (LEDs) [J].
Jandt, KD ;
Mills, RW ;
Blackwell, GB ;
Ashworth, SH .
DENTAL MATERIALS, 2000, 16 (01) :41-47