Compliance calibration for fracture testing of equine cortical bone

被引:10
作者
Malik, CL [1 ]
Gibeling, JC [1 ]
Martin, RB [1 ]
Stover, SM [1 ]
机构
[1] Univ Calif Davis, Dept Chem Engn & Mat Sci, Davis, CA 95616 USA
关键词
fracture mechanics; compliance; equine third metacarpal; cortical bone; modulus;
D O I
10.1016/S0021-9290(02)00009-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An experimental compliance calibration method for measuring crack length in fracture toughness tests of cortical bone was developed. Calibration tests were conducted on twenty compact type fracture specimens machined from the mid-diaphysis of five pairs of equine third metacarpal bones. Specimens were oriented for crack propagation in a direction transverse to the longitudinal axis of the bone. Specimen compliance was determined from the load vs. crack opening displacement record over a range of crack lengths from 0.48 to 0.75 times the specimen width. The results demonstrate that the compliance calibration method developed for isotropic materials can be used to determine crack length in bone, which is transversely isotropic. However, specimens from lateral and dorsal regions exhibited significantly different compliance calibrations even after differences in elastic modulus were taken into account in the normalized compliance. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:701 / 705
页数:5
相关论文
共 16 条
[1]  
*ASTM, 1993, E39990 ASTM
[2]   CRACK VELOCITY DEPENDENCE OF LONGITUDINAL FRACTURE IN BONE [J].
BEHIRI, JC ;
BONFIELD, W .
JOURNAL OF MATERIALS SCIENCE, 1980, 15 (07) :1841-1849
[3]   FRACTURE-MECHANICS OF BONE - THE EFFECTS OF DENSITY, SPECIMEN THICKNESS AND CRACK VELOCITY ON LONGITUDINAL FRACTURE [J].
BEHIRI, JC ;
BONFIELD, W .
JOURNAL OF BIOMECHANICS, 1984, 17 (01) :25-34
[4]   ORIENTATION DEPENDENCE OF THE FRACTURE-MECHANICS OF CORTICAL BONE [J].
BEHIRI, JC ;
BONFIELD, W .
JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) :863-&
[5]   FRACTURE TOUGHNESS OF COMPACT BONE [J].
BONFIELD, W ;
DATTA, PK .
JOURNAL OF BIOMECHANICS, 1976, 9 (03) :131-&
[6]  
Brown CU, 2000, J BIOMED MATER RES, V49, P380, DOI 10.1002/(SICI)1097-4636(20000305)49:3<380::AID-JBM11>3.3.CO
[7]  
2-N
[8]   NEW DEVELOPMENT OF THE J-BASED FRACTURE TESTING TECHNIQUE FOR CERAMIC-MATRIX COMPOSITES [J].
HASHIDA, T ;
LI, VC ;
TAKAHASHI, H .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1994, 77 (06) :1553-1561
[9]   The distribution of material properties in the equine third metacarpal bone serves to enhance sagittal bending [J].
Les, CM ;
Stover, SM ;
Keyak, JH ;
Taylor, KT ;
Willits, NH .
JOURNAL OF BIOMECHANICS, 1997, 30 (04) :355-361
[10]   Resistance to crack growth in human cortical bone is greater in shear than in tension [J].
Norman, TL ;
Nivargikar, SV ;
Burr, DB .
JOURNAL OF BIOMECHANICS, 1996, 29 (08) :1023-1031