State-of-the-art instruments for measuring radon thoron and their progeny in dwellings - A review

被引:63
作者
George, AC
机构
[1] Environmental Measurements Lab., U.S. Department of Energy, New York, NY 10014-3621
来源
HEALTH PHYSICS | 1996年 / 70卷 / 04期
关键词
radon; thoron; radon progeny; instrumentation;
D O I
10.1097/00004032-199604000-00001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radon and radon progeny measurements are conducted world-wide for the assessment of the radiation dose to workers and the general public, In the last 10 years, a variety of instruments have been developed that utilize different principles of detection for different measurement applications, The various instruments and methods used today depend on whether radon or radon/thoron progeny are being measured, the type of radiation being detected, and also the duration of the measurement, Other important design criteria are applicability, portability, convenience, reliability, and cost considerations. The instruments under consideration use the following detection systems: pulse ionization chambers, electret ionization chambers, scintillation detectors with zinc sulfide ZnS(Ag), alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, registration of nuclear tracks in solid-state materials, and gamma-ray spectrometry with NaI(TI) scintillation crystals or germanium lithium (GeLi) semiconductors, Discussed in this paper are the advantages and disadvantages of the various portable instrumentation used for measuring radon, thoron, and their progeny. Also provided is guidance for their application in the field.
引用
收藏
页码:451 / 463
页数:13
相关论文
共 31 条
[1]  
ALTER HW, 1981, HEALTH PHYS, V40, P693, DOI 10.1097/00004032-198105000-00008
[2]  
ALTSHULER BERNARD, 1963, HEALTH PHYS, V9, P293, DOI 10.1097/00004032-196303000-00005
[3]  
[Anonymous], 78 NCRP
[4]   A PULSE-COUNTING IONIZATION-CHAMBER FOR MEASURING THE RADON CONCENTRATION IN AIR [J].
BALTZER, P ;
GORSTEN, KG ;
BACKLIN, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (1-2) :357-364
[5]   INTERPRETATION OF THE RESPONSE OF CONTINUOUS RADON MONITORS TO TRANSIENT RADON CONCENTRATIONS [J].
BUSIGIN, A ;
VANDERVOOREN, AW ;
PHILLIPS, CR .
HEALTH PHYSICS, 1979, 37 (05) :659-667
[6]   A DIFFUSION BARRIER CHARCOAL ADSORPTION COLLECTOR FOR MEASURING RN CONCENTRATIONS IN INDOOR AIR [J].
COHEN, BL ;
NASON, R .
HEALTH PHYSICS, 1986, 50 (04) :457-463
[7]  
DOI M, 1992, RADIAT PROT DOSIM, V45, P425
[8]  
FISENNE IM, 1985, EML437 USDOE
[9]  
GENRICH V, 1990, D60488 GMBH
[10]  