A flux- and background-optimized version of the NanoSTAR small-angle X-ray scattering camera for solution scattering

被引:209
作者
Pedersen, JS
机构
[1] Aarhus Univ, Dept Chem, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ, iNANO Interdisciplinary Nanosci Ctr, DK-8000 Aarhus C, Denmark
关键词
D O I
10.1107/S0021889804004170
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A commercially available small-angle X-ray scattering camera, NanoSTAR from Bruker AXS, has been modified to optimize its use for weakly scattering solution samples. The original NanoSTAR is a pinhole camera with two Gobel mirrors for monochromating and making the beam parallel, and with a two-dimensional position-sensitive gas detector (HiSTAR) for data collection. The instrument has one integrated vacuum. It was constructed for position-resolved studies and thus has a small beam size at the sample position. In the present work, the instrumental configuration has been optimized by numerical calculations based on phase-space analysis and Monte Carlo simulations in order to obtain a higher flux. This has led to a setup in which the beam at the sample is larger and the collimation part of the instrument is longer, so that divergence of the beam is similar to that of the original camera. An extra pinhole is included after the Gobel mirrors to make the beam size well defined after the mirrors. The camera thus has genuine three-pinhole collimation. The use of electron-microscope pinholes minimizes parasitic scattering. At the University of Aarhus, the modified camera is installed on a powerful rotating-anode X-ray source (MacScience 6 kW Cu with a 0.3 x 0.3 mm effective source size). Measurements have been performed on a wide variety of weakly scattering samples, such as surfactant micelles, homopolymer solutions, block copolymer micelles, proteins etc. The data are routinely converted to absolute scale using the scattering from water as a primary standard. The standard configuration covers the range of scattering vectors from 0.01 to 0.35 Angstrom(-1) with a flux of 1.7 x 10(7) photons s(-1) for Cu Kalpha radiation at a generator power of 4.05 kW. The camera is easily converted to a high-resolution version covering 0.0037 to 0.22 Angstrom(-1) with a loss of flux of about a factor of 10, as well as to a position-resolved version.
引用
收藏
页码:369 / 380
页数:12
相关论文
共 34 条
[1]   A small-angle X-ray scattering apparatus for studying biological macromolecules in solution [J].
Bu, ZM ;
Perlo, A ;
Johnson, GE ;
Olack, G ;
Engelman, DM ;
Wyckoff, HW .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1998, 31 :533-543
[2]   Small-angle x-ray scattering studies of metastable intermediates of β-lactoglobulin isolated after heat-induced aggregation [J].
Carrotta, R ;
Arleth, L ;
Pedersen, JS ;
Bauer, R .
BIOPOLYMERS, 2003, 70 (03) :377-390
[3]  
ERLACHER K, 2003, THESIS U LEOBEN AUST
[4]   SOME DEVELOPMENTS AND APPLICATIONS OF MICROFOCUS X-RAY DIFFRACTION TECHNIQUES [J].
FRANKS, A .
BRITISH JOURNAL OF APPLIED PHYSICS, 1958, 9 (09) :349-352
[5]  
FRANKS A, 1953, P PHYS SOC LOND B, V68, P1054
[6]   A SMALL-ANGLE X-RAY-CAMERA USING A TWO-DIMENSIONAL MULTIWIRE PROPORTIONAL CHAMBER [J].
FURUNO, T ;
SASABE, H ;
IKEGAMI, A .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1987, 20 :16-22
[7]  
GORDON WG, 1961, J BIOL CHEM, V236, P431
[8]   THE 6-M POINT-FOCUSING SMALL-ANGLE X-RAY-SCATTERING CAMERA AT THE HIGH-INTENSITY X-RAY LABORATORY OF KYOTO-UNIVERSITY [J].
HAYASHI, H ;
HAMADA, F ;
SUEHIRO, S ;
MASAKI, N ;
OGAWA, T ;
MIYAJI, H .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1988, 21 (04) :330-339
[9]   ORNL 10-METER SMALL-ANGLE X-RAY-SCATTERING CAMERA [J].
HENDRICKS, RW .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1978, 11 (FEB) :15-30
[10]   DOUBLE FOCUSING X-RAY-CAMERA FOR USE WITH SYNCHROTRON RADIATION [J].
HENDRIX, J ;
KOCH, MHJ ;
BORDAS, J .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1979, 12 (OCT) :467-472